+254 721 331 808    training@upskilldevelopment.com

Home / Project Planning and Management Courses

Green Data Center Cooling Retrofit Project Management Course

Master green data center cooling retrofit project management, from energy audits and technology selection to procurement, phased installation, commissioning, and performance verification. Learn to reduce energy waste, control costs, protect critical operations, and deliver measurable sustainability improvements.
Duration: 5 Days Classroom & Online In-House Available Certificate on Completion

Training Registration & Schedule

Compare training options, fees and available dates, then register for your preferred session.

Online Training Registration

Training ModePlatformDurationFee per ParticipantRegistration
LIVE ONLINEInstructor-led training Zoom / Google MeetAttend from anywhere 5 days USD 900 Register Online →

Classroom / On-site Training Schedule

15 upcoming sessions

Swipe horizontally to see all columns →

Training DatesLocationTraining ModeFee per ParticipantRegistration
16 Nov 2026 – 20 Nov 20265 training days Nairobi CLASSROOM USD 1,500 Register Now →
16 Nov 2026 – 20 Nov 20265 training days Mombasa CLASSROOM USD 1,750 Register Now →
16 Nov 2026 – 20 Nov 20265 training days Kigali CLASSROOM USD 2,500 Register Now →
21 Dec 2026 – 25 Dec 20265 training days Nairobi CLASSROOM USD 1,500 Register Now →
21 Dec 2026 – 25 Dec 20265 training days Dubai CLASSROOM USD 4,900 Register Now →
21 Dec 2026 – 25 Dec 20265 training days Mombasa CLASSROOM USD 1,750 Register Now →
18 Jan 2027 – 22 Jan 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
15 Feb 2027 – 19 Feb 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
15 Mar 2027 – 19 Mar 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
19 Apr 2027 – 23 Apr 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
17 May 2027 – 21 May 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
21 Jun 2027 – 25 Jun 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
19 Jul 2027 – 23 Jul 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
16 Aug 2027 – 20 Aug 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
20 Sep 2027 – 24 Sep 20275 training days Nairobi CLASSROOM USD 1,500 Register Now →
Need registration assistance? Contact training@upskilldevelopment.com for training dates, invoices and invitation letters.

Nairobi, Kenya Classroom/On-site Training Schedule

Course Date Location Fee Enroll
16/11/2026 to 20/11/2026 Nairobi 1,500 USD Register
21/12/2026 to 25/12/2026 Nairobi 1,500 USD Register
18/01/2027 to 22/01/2027 Nairobi 1,500 USD Register
15/02/2027 to 19/02/2027 Nairobi 1,500 USD Register
15/03/2027 to 19/03/2027 Nairobi 1,500 USD Register
19/04/2027 to 23/04/2027 Nairobi 1,500 USD Register
17/05/2027 to 21/05/2027 Nairobi 1,500 USD Register
21/06/2027 to 25/06/2027 Nairobi 1,500 USD Register
19/07/2027 to 23/07/2027 Nairobi 1,500 USD Register
16/08/2027 to 20/08/2027 Nairobi 1,500 USD Register
20/09/2027 to 24/09/2027 Nairobi 1,500 USD Register
18/10/2027 to 22/10/2027 Nairobi 1,500 USD Register
15/11/2027 to 19/11/2027 Nairobi 1,500 USD Register
20/12/2027 to 24/12/2027 Nairobi 1,500 USD Register

Mombasa, Kenya Classroom/On-site Training Schedule

Course Date Location Fee Enroll
16/11/2026 to 20/11/2026 Mombasa 1,750 USD Register
21/12/2026 to 25/12/2026 Mombasa 1,750 USD Register

Kigali, Rwanda Classroom/On-site Training Schedule

Course Date Location Fee Enroll
16/11/2026 to 20/11/2026 Kigali 2,500 USD Register

Dubai, UAE Classroom/On-site Training Schedule

Course Date Location Fee Enroll
21/12/2026 to 25/12/2026 Dubai 4,900 USD Register

Dar es Salaam, Tanzania Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Kampala, Uganda Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Course Introduction

Green data center cooling retrofits are becoming increasingly important as organizations seek to reduce energy consumption, improve operational efficiency, lower carbon emissions, and accommodate growing computing workloads. Cooling systems can account for a significant proportion of data center energy use, making their modernization an important opportunity for improving overall facility performance. However, upgrading cooling infrastructure within an operational data center requires careful coordination of engineering activities, equipment procurement, operational continuity, financial planning, and environmental objectives. This course provides participants with practical project management knowledge for planning, coordinating, executing, and monitoring green data center cooling retrofit projects while balancing energy efficiency, equipment reliability, capital expenditure, and business continuity requirements.

Planning a cooling retrofit begins with assessing the existing facility, identifying inefficiencies, establishing baseline performance, and evaluating available modernization options. Project teams must understand the existing cooling architecture, airflow patterns, rack densities, heat loads, power distribution, environmental controls, and operational constraints before selecting suitable interventions. Potential improvements may include precision cooling upgrades, hot aisle and cold aisle containment, variable-speed fans, high-efficiency chillers, economizers, liquid cooling systems, and intelligent environmental monitoring. This course examines feasibility assessments, energy audits, technical condition surveys, cooling demand analysis, and business case development. Participants will learn how to establish measurable objectives, evaluate retrofit alternatives, and prioritize improvements according to expected energy savings, implementation complexity, and long-term operational value.

Managing a green cooling retrofit in an active data center introduces challenges that differ from those encountered during new facility construction. Critical computing services must remain available while contractors replace equipment, modify pipework, install controls, improve airflow management, and commission upgraded cooling systems. These activities require detailed shutdown planning, phased implementation, contingency arrangements, contractor coordination, and clear communication with operations teams. Participants will explore how to develop work breakdown structures, critical path schedules, resource plans, procurement strategies, and method statements that support safe and controlled implementation. The course also examines change management, maintenance window coordination, temporary cooling arrangements, equipment delivery dependencies, and commissioning readiness to reduce the risk of service disruption.

Effective cooling retrofit management requires coordination among mechanical engineers, electrical engineers, data center operators, facilities managers, energy specialists, equipment manufacturers, construction contractors, and environmental compliance teams. Project managers must ensure that the proposed design is compatible with existing infrastructure, that equipment specifications match actual operating requirements, and that installation activities meet applicable safety and quality standards. Financial control is equally important because retrofit projects involve capital investment, potential operating savings, maintenance implications, and uncertain energy price assumptions. This course addresses project budgeting, lifecycle cost analysis, procurement governance, supplier evaluation, contract administration, risk assessment, and performance reporting. Participants will learn to assess cost-benefit scenarios and maintain accountability throughout the retrofit project lifecycle.

Environmental performance and sustainability are central to green data center cooling modernization. Organizations increasingly measure energy efficiency, carbon emissions, water consumption, renewable energy integration, and equipment lifecycle impacts when evaluating infrastructure investments. Cooling strategies must therefore be selected according to local climate conditions, water availability, facility design, computing density, and operational requirements. This course examines power usage effectiveness (PUE), cooling system efficiency, water usage effectiveness (WUE), energy measurement, heat reuse opportunities, refrigerant management, and environmental performance verification. Participants will also consider emerging approaches such as direct-to-chip liquid cooling, immersion cooling, AI-assisted cooling optimization, digital twins, and predictive maintenance, while recognizing that the suitability of each technology depends on workload characteristics and site conditions.

By the end of the course, participants will understand how to manage a green data center cooling retrofit from initial assessment and feasibility analysis through design approval, procurement, installation, testing, and operational handover. They will develop practical skills in schedule management, cost control, contractor coordination, risk mitigation, commissioning, and sustainability performance measurement. The training emphasizes the importance of protecting critical workloads, validating expected energy savings, documenting operational changes, and maintaining reliable cooling performance after implementation. Through realistic project scenarios and planning exercises, participants will be better prepared to deliver retrofit projects that improve energy efficiency, support environmental commitments, strengthen infrastructure resilience, and provide measurable long-term business benefits.

Duration

5 days

Who Should Attend

  • Project managers responsible for data center cooling modernization projects involving mechanical systems, electrical infrastructure, energy efficiency improvements, and sustainability targets.

  • Data center facilities managers overseeing cooling plant operations, environmental controls, chilled water systems, air handling equipment, and facility performance optimization.

  • Mechanical engineers involved in cooling system design, chiller replacement, airflow management, heat transfer analysis, piping modifications, and liquid cooling implementation.

  • Electrical engineers responsible for power distribution upgrades, cooling equipment electrical connections, backup arrangements, control systems, and electrical safety during retrofit works.

  • Data center operations managers coordinating maintenance windows, equipment shutdowns, temporary cooling arrangements, operational readiness, and continuity of critical IT services.

  • Energy managers and sustainability professionals responsible for conducting energy audits, establishing performance baselines, measuring efficiency improvements, and reporting environmental outcomes.

  • Infrastructure and critical facilities engineers evaluating cooling capacity, rack density, thermal management, redundancy requirements, and compatibility with existing data center systems.

  • Procurement and supply chain professionals managing the sourcing of chillers, cooling distribution units, pumps, heat exchangers, control equipment, sensors, and specialist installation services.

  • Contract administrators and commercial managers overseeing equipment supply contracts, construction agreements, service level obligations, warranties, project claims, and contractor performance.

  • Health, safety, and environmental professionals responsible for construction safety, refrigerant handling, water management, environmental controls, and compliance during retrofit implementation.

  • Quality assurance specialists responsible for installation inspections, technical documentation, commissioning procedures, performance verification, and corrective action management.

  • Financial analysts and project cost controllers involved in capital budgeting, lifecycle cost analysis, energy savings calculations, investment appraisal, and financial performance reporting.

  • Building management systems and automation specialists responsible for integrating cooling equipment, environmental sensors, alarms, control logic, and centralized monitoring platforms.

  • Data center consultants and engineering contractors seeking structured approaches to planning, executing, and evaluating sustainable cooling infrastructure upgrades.

  • IT infrastructure and capacity planning professionals assessing the implications of higher-density computing, AI workloads, server refresh cycles, and liquid cooling requirements for existing data center facilities.

Course Objectives

  • Develop comprehensive project management plans for green data center cooling retrofits, defining project scope, sustainability targets, technical deliverables, implementation milestones, responsibilities, and acceptance criteria.

  • Assess existing cooling infrastructure through energy audits, equipment condition surveys, thermal mapping, airflow analysis, cooling capacity reviews, and evaluation of current operational performance.

  • Evaluate retrofit alternatives, including high-efficiency chillers, airflow containment, economizers, variable-speed equipment, liquid cooling, and intelligent control systems, according to site-specific requirements.

  • Prepare project budgets, investment appraisals, and lifecycle cost analyses that consider capital expenditure, energy savings, maintenance costs, water consumption, equipment replacement, and operational benefits.

  • Develop phased implementation schedules that coordinate procurement, equipment delivery, construction activities, shutdown windows, temporary cooling, testing, and commissioning while protecting critical services.

  • Apply procurement and contract management techniques to evaluate suppliers, verify equipment specifications, manage contractor performance, control variations, and maintain compliance with contractual obligations.

  • Identify and mitigate technical, operational, environmental, financial, safety, and schedule risks associated with modifying cooling systems in live data center environments.

  • Establish quality assurance, commissioning, and performance verification procedures that confirm cooling capacity, temperature stability, system reliability, control functionality, and compliance with approved design requirements.

  • Measure sustainability outcomes using appropriate energy efficiency, water efficiency, carbon emissions, and lifecycle performance indicators to verify whether the retrofit achieves its intended environmental objectives.

  • Implement operational handover, maintenance planning, monitoring, change control, and continuous improvement processes that sustain cooling efficiency and reliability throughout the upgraded system's service life.

Comprehensive Course Outline

Module 1: Fundamentals of Green Data Center Cooling and Retrofit Management

  • Explain data center thermal management principles, heat generation, airflow patterns, cooling loads, environmental conditions, and the relationship between cooling performance and IT equipment reliability.

  • Examine conventional cooling architectures, including computer room air conditioning, computer room air handlers, chilled water systems, cooling towers, heat exchangers, and associated distribution equipment.

  • Identify the objectives, benefits, constraints, and lifecycle stages of green cooling retrofit projects in operational data centers with continuous availability requirements.

  • Define project governance arrangements, stakeholder responsibilities, sustainability objectives, technical deliverables, and performance criteria for successful cooling modernization.

Module 2: Existing Infrastructure Assessment and Energy Audit

  • Conduct baseline assessments of cooling equipment, electrical consumption, thermal conditions, rack density, airflow management, maintenance history, and existing control strategies.

  • Analyze temperature distribution, humidity conditions, hot spots, bypass airflow, recirculation, chilled water performance, and cooling capacity utilization to identify operational inefficiencies.

  • Review facility energy data, equipment operating profiles, environmental monitoring records, maintenance costs, and available utility information to establish a reliable performance baseline.

  • Prepare technical assessment reports that document inefficiencies, operational constraints, infrastructure deficiencies, improvement opportunities, and recommendations for further engineering investigation.

Module 3: Retrofit Design Options and Cooling Technology Selection

  • Evaluate high-efficiency chillers, variable-speed pumps and fans, air-side and water-side economizers, cooling containment, and optimized cooling distribution according to facility requirements.

  • Examine direct-to-chip liquid cooling, rear-door heat exchangers, immersion cooling, and coolant distribution units for facilities supporting high-density computing and AI workloads.

  • Assess control system modernization, intelligent temperature management, environmental sensors, predictive maintenance, and automated cooling optimization using real-time operational data.

  • Compare retrofit options using technical compatibility, expected energy savings, installation complexity, reliability, maintainability, water requirements, lifecycle costs, and future scalability.

Module 4: Project Planning, Budgeting, and Business Case Development

  • Develop project charters, work breakdown structures, stakeholder registers, responsibility matrices, implementation milestones, and detailed schedules for cooling retrofit activities.

  • Prepare cost estimates covering equipment acquisition, engineering design, construction, piping, electrical modifications, controls integration, temporary cooling, testing, and contingency provisions.

  • Conduct lifecycle cost analysis, return on investment assessments, payback calculations, and sensitivity analysis using realistic energy prices, maintenance costs, and expected savings.

  • Establish project performance indicators, budget controls, approval gates, risk-adjusted forecasts, and reporting arrangements that maintain financial and delivery accountability.

Module 5: Procurement, Contractor Coordination, and Contract Management

  • Develop technical procurement specifications for chillers, pumps, cooling distribution units, heat exchangers, sensors, control systems, piping components, and associated installation services.

  • Evaluate suppliers according to equipment efficiency, operating capacity, reliability, refrigerant characteristics, compatibility, delivery lead times, warranties, and technical support.

  • Coordinate contractor selection, site access, equipment delivery, material storage, installation sequencing, permit requirements, and interfaces between mechanical and electrical work packages.

  • Administer contracts, purchase orders, variations, delivery inspections, payment milestones, claims, warranties, and supplier performance reviews throughout project implementation.

Module 6: Live Data Center Retrofit Execution and Continuity Planning

  • Develop phased construction plans and method statements that sequence equipment replacement, pipework modifications, airflow improvements, control upgrades, and electrical connections safely.

  • Coordinate maintenance windows, shutdown approvals, redundancy checks, temporary cooling arrangements, workload relocation where feasible, and contingency measures for critical operations.

  • Establish communication procedures between data center operations, engineering teams, contractors, IT administrators, security personnel, and business stakeholders during implementation.

  • Apply change management, work permits, lockout and tagout procedures where applicable, installation checklists, progress monitoring, and escalation protocols to reduce operational disruption.

Module 7: Risk Management, Safety, and Environmental Compliance

  • Develop project risk registers covering cooling capacity shortfalls, unexpected infrastructure defects, equipment delivery delays, thermal instability, cost overruns, and service interruption.

  • Assess hazards associated with electrical work, rotating machinery, pressurized systems, refrigerants, water leaks, lifting operations, and construction activities in restricted technical environments.

  • Coordinate applicable environmental and safety requirements involving refrigerant management, chemical handling, water discharge, waste disposal, equipment decommissioning, and worker protection.

  • Implement risk mitigation plans, emergency procedures, quality controls, incident reporting, and contingency arrangements that support safe execution and reliable cooling performance.

Module 8: Commissioning, Testing, and Performance Verification

  • Develop commissioning plans covering installation inspections, equipment startup, controls verification, chilled water balancing, airflow testing, sensor calibration, and system integration.

  • Verify cooling capacity, temperature stability, equipment redundancy, alarms, control sequences, energy consumption, and response to changing IT loads under controlled test conditions.

  • Establish performance measurement procedures to compare post-retrofit results against baseline data and approved targets for efficiency, reliability, water consumption, and operating cost.

  • Document test results, defects, corrective actions, acceptance certificates, operating parameters, commissioning records, and formal approval for transition into normal operations.

Module 9: Sustainability Metrics, Emerging Technologies, and Intelligent Optimization

  • Calculate and interpret power usage effectiveness, water usage effectiveness, cooling-related energy consumption, carbon emissions, and other indicators relevant to data center sustainability.

  • Evaluate heat recovery, waste heat reuse, renewable energy integration, water-efficient cooling strategies, and refrigerant alternatives according to site conditions and environmental objectives.

  • Examine AI-assisted cooling optimization, digital twins, predictive maintenance, computational fluid dynamics, and automated control systems for improving operational efficiency.

  • Assess emerging liquid cooling technologies, high-density rack requirements, changing AI workloads, energy reporting expectations, and evolving sustainability standards when planning future retrofit phases.

Module 10: Operational Handover, Maintenance, and Continuous Improvement

  • Prepare operational handover documentation covering equipment registers, system diagrams, control sequences, maintenance schedules, operating procedures, warranties, and emergency response arrangements.

  • Establish performance monitoring dashboards, maintenance indicators, energy reporting processes, temperature alarm thresholds, and procedures for investigating abnormal cooling behavior.

  • Develop preventive and predictive maintenance programs for chillers, pumps, heat exchangers, fans, cooling distribution units, sensors, valves, and automated control systems.

  • Complete project closure reports, final cost reconciliation, benefits realization reviews, lessons-learned documentation, and recommendations for ongoing optimization and future infrastructure upgrades.

Training Approach

This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.

Tailor-Made Course

This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808

Training Venue 

The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.

Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant

Certification

Participants will be issued with Upskill certificate upon completion of this course.

Airport Pickup and Accommodation

Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808

Terms of Payment:

Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.

Choose Your Training Format

Attend a scheduled session or request a customized programme for your organization.

Classroom Training

Attend instructor-led training at one of our scheduled training locations.

Live Online Training

Join interactive instructor-led sessions remotely from your office or home.

In-House Training

Customize the course content, dates and delivery for your team or organization.

Certification

Participants who successfully complete the programme receive a Certificate of Completion from Upskill Development Institute.

Request Course Information

Need a Tailor-Made Programme?

We can customize the course content, duration, schedule and delivery format to match your organization's objectives.

Dates & Fees Enquire Now

Organizations we've served

Some of Our Recent Clients

We support professional development and institutional capacity building for organizations across a wide range of sectors. Explore a selection of organizations featured in our client portfolio.

SNV logoSNV
National Communications Authority logoNational Communications Authority
Masinde Muliro University of Science and Technology logoMasinde Muliro University of Science and Technology
Kenya Medical Research Institute logoKenya Medical Research Institute
Save Lamu logoSave Lamu
UNICEF logoUNICEF
Fairtrade Africa logoFairtrade Africa
World Agroforestry (ICRAF) logoWorld Agroforestry (ICRAF)
CPI logoCPI
Food and Agriculture Organization (FAO) logoFood and Agriculture Organization (FAO)
University of Southampton logoUniversity of Southampton
Ngali Holdings logoNgali Holdings
STOPAIDS logoSTOPAIDS
International Fertilizer Development Center (IFDC) logoInternational Fertilizer Development Center (IFDC)
Wide Communications logoWide Communications

Learn. Apply. Grow.

Build skills that make a difference at work

Upskill Development Institute offers practical professional training, customized group programmes and flexible learning options to help individuals and organizations strengthen performance.

Chat with us on WhatsApp