NOTE: To view the training dates and registration button clearly put your mobile phone, tablet on landscape layout. Thank you
| Training Mode | Platform | Fee | Enroll |
|---|---|---|---|
| Online Training | Zoom/ Google Meet | 900USD | Register |
| Course Date | Location | Fee | Enroll |
|---|---|---|---|
| 21/09/2026 to 25/09/2026 | Nairobi | 1,500 USD | Register |
| 21/09/2026 to 25/09/2026 | Mombasa | 1,750 USD | Register |
| 21/09/2026 to 25/09/2026 | Dubai | 4,900 USD | Register |
| 19/10/2026 to 23/10/2026 | Nairobi | 1,500 USD | Register |
| 19/10/2026 to 23/10/2026 | Mombasa | 1,750 USD | Register |
| 16/11/2026 to 20/11/2026 | Nairobi | 1,500 USD | Register |
| 16/11/2026 to 20/11/2026 | Mombasa | 1,750 USD | Register |
| 16/11/2026 to 20/11/2026 | Kigali | 2,500 USD | Register |
| 21/12/2026 to 25/12/2026 | Nairobi | 1,500 USD | Register |
| 21/12/2026 to 25/12/2026 | Dubai | 4,900 USD | Register |
| 21/12/2026 to 25/12/2026 | Mombasa | 1,750 USD | Register |
| 18/01/2027 to 22/01/2027 | Nairobi | 1,500 USD | Register |
| 15/02/2027 to 19/02/2027 | Nairobi | 1,500 USD | Register |
| 15/03/2027 to 19/03/2027 | Nairobi | 1,500 USD | Register |
| 19/04/2027 to 23/04/2027 | Nairobi | 1,500 USD | Register |
Course Introduction
Electrical Relay Coordination Workshop Training Course is designed to provide participants with comprehensive knowledge and practical skills for designing, analyzing, testing, and optimizing protective relay coordination in electrical power systems. The course emphasizes relay coordination principles, fault analysis, protection selectivity, relay settings, coordination studies, and system reliability to ensure safe, dependable, and efficient protection of electrical transmission, distribution, and industrial power networks in accordance with international standards and engineering best practices.
Protective relay coordination is essential for ensuring that only the affected portion of an electrical system is isolated during fault conditions while maintaining continuity of service for healthy sections of the network. Poor relay coordination can result in unnecessary outages, equipment damage, safety hazards, and increased operational costs. This course equips participants with the technical competence to develop coordinated protection schemes, perform relay setting calculations, evaluate fault scenarios, and verify protection system performance using structured engineering methodologies.
Participants will gain practical knowledge of overcurrent relay coordination, earth fault protection, directional protection, differential protection, distance protection, relay characteristics, time-current coordination curves, fault current calculations, protection grading, relay testing, circuit breaker coordination, relay commissioning, disturbance analysis, and protection performance evaluation. Through practical workshop exercises, case studies, and real-world utility examples, participants will develop the confidence to perform comprehensive relay coordination studies and improve power system reliability.
The course also explores the integration of relay coordination with Supervisory Control and Data Acquisition (SCADA), Energy Management Systems (EMS), Distribution Management Systems (DMS), Intelligent Electronic Devices (IEDs), IEC 61850 communication networks, digital substations, synchrophasor technologies, Computerized Maintenance Management Systems (CMMS), Enterprise Asset Management (EAM), and power system simulation software. Participants will understand how coordinated protection systems improve fault isolation, operational efficiency, maintenance planning, and grid resilience.
Emerging technologies including Artificial Intelligence (AI), machine learning, Industrial Internet of Things (IIoT), predictive analytics, adaptive protection systems, digital twins, cloud-based relay management platforms, wide-area protection systems, cybersecurity for protection systems, and smart grid automation are transforming protective relay coordination. This course introduces these innovations while emphasizing engineering excellence, operational reliability, regulatory compliance, safety, sustainability, and continuous improvement.
Upon successful completion, participants will possess the practical competence to design, configure, test, evaluate, troubleshoot, and continuously improve electrical relay coordination systems. They will be equipped to enhance power system reliability, optimize protection selectivity, reduce equipment damage, improve operational safety, strengthen regulatory compliance, and support the reliable operation of modern electrical power systems.
Duration
5 days
Who Should Attend
Protection Engineers
Electrical Engineers
Power System Engineers
Relay Protection Engineers
Substation Engineers
Distribution Engineers
Transmission Engineers
Commissioning Engineers
Maintenance Engineers
Testing and Commissioning Technicians
SCADA Engineers
Utility Operations Engineers
Asset Management Engineers
Electrical Consultants
Power System Planning Engineers
Course Objectives
Develop comprehensive knowledge of relay coordination principles, protection philosophies, and internationally recognized electrical protection engineering standards.
Understand coordination techniques for overcurrent, earth fault, directional, differential, and distance protection systems operating within industrial and utility power networks.
Apply engineering best practices for relay coordination studies, relay grading, protection settings calculations, and fault current analysis to improve network reliability.
Perform systematic relay testing, commissioning, troubleshooting, and maintenance using modern testing equipment and internationally accepted engineering procedures.
Strengthen competency in integrating relay coordination with SCADA, EMS, DMS, IEC 61850 communication networks, Intelligent Electronic Devices, and digital substations.
Improve power system reliability by optimizing relay selectivity, sensitivity, discrimination, and operating times for electrical protection systems.
Conduct comprehensive protection coordination studies, relay performance evaluations, fault investigations, and compliance assessments supporting safe electrical operations.
Analyze disturbance records, relay event logs, oscillography data, and protection system performance indicators to support continuous operational improvement.
Explore emerging technologies including artificial intelligence, adaptive protection, predictive analytics, IIoT, digital twins, cloud-based relay management platforms, and cybersecurity solutions.
Build practical competence to configure, document, audit, and continuously improve relay coordination programs while ensuring operational safety, reliability, regulatory compliance, and asset protection.
Course Outline
Module 1: Fundamentals of Protective Relay Coordination
Principles of protective relay coordination for reliable electrical power system protection
Understanding protection philosophy, selectivity, discrimination, and coordination objectives
International standards governing protective relay applications and coordination practices
Roles and responsibilities of protection engineers in relay coordination studies
Module 2: Fault Analysis and Relay Characteristics
Performing fault current calculations supporting effective relay coordination studies
Understanding relay operating characteristics and time-current performance curves
Evaluating symmetrical and unsymmetrical faults affecting protection system operation
Selecting relay characteristics suitable for industrial and utility applications
Module 3: Overcurrent and Earth Fault Relay Coordination
Coordinating overcurrent relays for dependable feeder and equipment protection systems
Applying earth fault relay coordination for grounded and ungrounded electrical networks
Developing relay grading strategies to improve selective fault isolation effectively
Optimizing protection settings using engineering calculation methodologies accurately
Module 4: Advanced Relay Protection Applications
Coordinating directional protection schemes for interconnected electrical power networks
Applying differential relay coordination for transformers, generators, and busbars safely
Utilizing distance protection coordination for transmission line protection systems
Evaluating backup protection strategies supporting secure system fault clearance
Module 5: Relay Testing and Commissioning
Conducting secondary injection testing for relay verification and performance validation
Performing relay commissioning procedures before energizing electrical protection systems
Inspecting circuit breakers supporting coordinated relay operation during faults
Troubleshooting relay coordination issues using structured diagnostic techniques effectively
Module 6: Digital Protection Systems and IEC 61850
Integrating relay coordination with SCADA, EMS, and DMS platforms efficiently
Configuring Intelligent Electronic Devices supporting advanced protection applications
Applying IEC 61850 communication standards within modern digital substations successfully
Managing protection event records and disturbance analysis using digital technologies
Module 7: Coordination Studies and Performance Evaluation
Conducting comprehensive relay coordination studies using engineering software applications
Evaluating relay performance through fault simulation and operational analysis methods
Assessing protection system effectiveness using key reliability performance indicators
Developing corrective actions to improve relay coordination and protection reliability
Module 8: Emerging Technologies in Relay Protection
Artificial intelligence supporting adaptive relay coordination and fault prediction capabilities
Industrial Internet of Things enabling real-time protection monitoring and diagnostics
Digital twins improving relay coordination analysis and system performance evaluation
Cybersecurity strategies protecting intelligent relay systems and digital substations effectively
Module 9: Maintenance, Documentation, and Compliance
Establishing preventive maintenance programs for protective relay systems effectively
Conducting relay coordination audits supporting regulatory compliance and operational excellence
Managing protection documentation, engineering records, and relay setting databases securely
Integrating relay coordination with enterprise asset management and maintenance systems
Module 10: Best Practices and Continuous Improvement
Developing comprehensive relay coordination management frameworks for power system protection
Measuring relay protection performance using internationally recognized performance indicators
Benchmarking relay coordination practices against global electrical engineering standards
Implementing continuous improvement initiatives supporting resilient electrical protection systems
Training Approach
This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.
Tailor-Made Course
This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808
Training Venue
The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.
Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant
Certification
Participants will be issued with Upskill certificate upon completion of this course.
Airport Pickup and Accommodation
Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808
Terms of Payment:
Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.
| Training Mode | Platform | Fee | Enroll |
|---|---|---|---|
| Online Training | Zoom/ Google Meet | 900USD | Register |
| Course Date | Location | Fee | Enroll |
|---|---|---|---|
| 21/09/2026 to 25/09/2026 | Nairobi | 1,500 USD | Register |
| 21/09/2026 to 25/09/2026 | Mombasa | 1,750 USD | Register |
| 21/09/2026 to 25/09/2026 | Dubai | 4,900 USD | Register |
| 19/10/2026 to 23/10/2026 | Nairobi | 1,500 USD | Register |
| 19/10/2026 to 23/10/2026 | Mombasa | 1,750 USD | Register |
| 16/11/2026 to 20/11/2026 | Nairobi | 1,500 USD | Register |
| 16/11/2026 to 20/11/2026 | Mombasa | 1,750 USD | Register |
| 16/11/2026 to 20/11/2026 | Kigali | 2,500 USD | Register |
| 21/12/2026 to 25/12/2026 | Nairobi | 1,500 USD | Register |
| 21/12/2026 to 25/12/2026 | Dubai | 4,900 USD | Register |
| 21/12/2026 to 25/12/2026 | Mombasa | 1,750 USD | Register |
| 18/01/2027 to 22/01/2027 | Nairobi | 1,500 USD | Register |
| 15/02/2027 to 19/02/2027 | Nairobi | 1,500 USD | Register |
| 15/03/2027 to 19/03/2027 | Nairobi | 1,500 USD | Register |
| 19/04/2027 to 23/04/2027 | Nairobi | 1,500 USD | Register |
We support the development of a skilled and confident workforce to meet the changing demands of growing sectors by offering the best possible training to enable them to fulfil learning goals.
Make a Mark in You Day to Day work