Course Introduction
The rapid expansion of artificial intelligence, high-performance computing, and accelerated computing workloads is transforming data center infrastructure design. AI servers equipped with high-performance GPUs and specialized processors generate significantly higher power densities and thermal loads than conventional computing equipment. These requirements demand coordinated engineering across liquid cooling systems, electrical power distribution, rack infrastructure, monitoring technologies, and facility-level capacity planning. This course examines the integrated engineering principles required to develop AI-ready data centers capable of supporting high-density computing while maintaining reliability, energy efficiency, scalability, and operational safety.
The AI-Ready Data Center Liquid Cooling, Power Distribution and Rack Infrastructure Integration Training Course provides advanced technical knowledge of designing, integrating, and operating infrastructure for GPU-intensive and high-performance computing environments. It explores the relationships between IT equipment power requirements, rack-level electrical distribution, liquid cooling architectures, heat rejection systems, and supporting facility infrastructure. Participants examine how compute density, rack configuration, electrical topology, cooling capacity, and physical infrastructure constraints influence one another. The program emphasizes coordinated engineering rather than treating power, cooling, and rack systems as independent design disciplines.
A major focus of the course is liquid cooling engineering for AI infrastructure. Participants examine direct-to-chip liquid cooling, rear-door heat exchangers, single-phase immersion cooling, and supporting chilled water and facility water systems. The course covers coolant distribution units, manifolds, pumps, heat exchangers, piping networks, flow control, filtration, leak detection, and thermal performance monitoring. Particular attention is given to coolant compatibility, material selection, hydraulic balancing, differential pressure, supply and return temperatures, heat transfer efficiency, and equipment protection. Participants also explore how liquid cooling systems must be engineered to accommodate changing GPU thermal loads, variable rack densities, and continuous AI workloads.
The program also examines electrical power distribution strategies for high-density AI racks. Participants explore utility and medium-voltage infrastructure, transformers, UPS systems, generators, switchgear, busway systems, remote power panels, rack power distribution units, and branch circuit protection. It addresses power density calculations, load balancing, redundancy, transient demand, power quality, protection coordination, and electrical capacity management. The course explains how to coordinate facility-level electrical design with rack-level power requirements, including high-current distribution arrangements, equipment connectivity, monitoring, and emerging rack power architectures. It also considers the implications of high-density GPU deployments and evolving direct-current distribution concepts.
Rack infrastructure integration is another central element of the training. Participants examine structural loading, rack dimensions, equipment mounting, cable management, containment, liquid cooling connections, power entry arrangements, service clearances, and maintenance accessibility. The program explores the physical integration of GPU servers, networking equipment, rack manifolds, coolant distribution connections, busbars, intelligent power distribution units, and monitoring devices. It also addresses the practical challenges of coordinating rack manufacturers, server vendors, electrical contractors, cooling specialists, and data center operators. These considerations are particularly important when deploying large-scale AI clusters with tightly coupled power, thermal, and network requirements.
The course concludes by examining integrated testing, commissioning, operational monitoring, and lifecycle optimization for AI-ready data center infrastructure. Participants learn how to validate cooling performance, verify electrical capacity, test leak detection systems, assess rack-level power and thermal conditions, and coordinate integrated systems testing. The program also explores digital monitoring, predictive maintenance, energy optimization, failure analysis, and capacity expansion planning. By the end of the training, participants will be better equipped to develop integrated infrastructure strategies for AI workloads, reduce deployment risks, improve thermal and electrical performance, and support the scalable operation of next-generation high-density data centers.
Duration
10 days
Who Should Attend
-
Data center design engineers responsible for developing infrastructure architectures for AI and high-performance computing environments.
-
Data center facilities managers overseeing high-density electrical, mechanical, and rack infrastructure operations.
-
Electrical engineers involved in UPS systems, generators, transformers, switchgear, busway distribution, and rack-level power engineering.
-
Mechanical and HVAC engineers responsible for liquid cooling systems, heat rejection, chilled water networks, and thermal management.
-
Data center cooling specialists working with direct-to-chip cooling, immersion cooling, CDUs, and liquid distribution infrastructure.
-
AI infrastructure engineers responsible for GPU servers, accelerated computing platforms, and high-density rack deployments.
-
Rack integration engineers involved in server mounting, power distribution, coolant connections, and physical infrastructure configuration.
-
Commissioning engineers responsible for electrical testing, cooling validation, integrated systems testing, and infrastructure acceptance.
-
Data center project managers coordinating electrical, mechanical, IT, and rack infrastructure installation activities.
-
Critical facilities engineers responsible for equipment reliability, capacity management, and operational readiness.
-
Data center consultants supporting AI facility design, infrastructure modernization, and high-density computing deployments.
-
Energy and sustainability managers seeking to optimize power consumption and cooling efficiency in AI data centers.
-
BMS, SCADA, and DCIM specialists responsible for monitoring integrated power, cooling, and rack infrastructure.
-
Technical procurement and engineering professionals involved in selecting AI server racks, cooling equipment, electrical distribution systems, and associated infrastructure.
Course Objectives
-
Understand the infrastructure requirements of AI-ready data centers, including GPU computing densities, thermal loads, electrical demand, rack configurations, and scalability considerations.
-
Evaluate direct-to-chip, rear-door heat exchanger, and immersion cooling technologies for high-density AI computing applications.
-
Design liquid cooling distribution architectures incorporating CDUs, pumps, manifolds, heat exchangers, piping networks, filtration, and leak detection.
-
Calculate rack-level thermal requirements, coolant flow rates, heat transfer loads, supply and return temperatures, and cooling system operating parameters.
-
Develop electrical distribution strategies for AI racks, including UPS systems, generators, switchgear, busways, rack PDUs, and branch circuit protection.
-
Assess high-density rack power requirements, electrical loading, redundancy arrangements, power quality, transient demand, and future expansion capacity.
-
Integrate liquid cooling connections, electrical distribution, server mounting, cable management, and structural requirements into coordinated rack infrastructure designs.
-
Understand the engineering implications of GPU server configurations, high-speed networking, rack connectivity, and concentrated AI cluster deployments.
-
Apply integrated design principles to coordinate facility cooling capacity, electrical infrastructure, rack layouts, and IT equipment deployment requirements.
-
Establish monitoring strategies for electrical consumption, coolant temperature, pressure, flow, leakage, rack thermal conditions, and equipment health.
-
Develop commissioning and testing procedures for validating electrical performance, liquid cooling functionality, leak protection, and integrated infrastructure reliability.
-
Implement operational optimization and lifecycle management strategies that improve energy efficiency, maintainability, availability, and scalability of AI-ready facilities.
Comprehensive Course Outline
Module 1: AI-Ready Data Center Infrastructure Fundamentals
-
Evolution of AI computing infrastructure and the impact of GPU clusters, accelerated processors, high-performance networking, and intensive computational workloads on facility design.
-
Comparison of conventional data center infrastructure and AI-ready environments in terms of rack density, power consumption, cooling demand, and equipment configuration.
-
Understanding relationships between compute architecture, electrical capacity, thermal management, network infrastructure, physical rack design, and facility operations.
-
Assessment of AI data center design requirements involving scalability, redundancy, availability, maintainability, energy efficiency, and infrastructure lifecycle planning.
Module 2: AI Server Architecture and High-Density Rack Engineering
-
Understanding GPU servers, accelerator platforms, high-performance CPUs, memory systems, and networking equipment used in AI training and inference environments.
-
Evaluation of rack-level power and thermal characteristics based on server configuration, processor density, workload intensity, and equipment operating conditions.
-
Rack structural design covering dimensions, weight limits, mounting arrangements, equipment clearances, containment, and service accessibility.
-
Planning rack layouts for AI clusters, including equipment positioning, cable routing, power entry, cooling connections, and infrastructure expansion requirements.
Module 3: Liquid Cooling Technologies for AI Data Centers
-
Technical comparison of direct-to-chip liquid cooling, rear-door heat exchangers, single-phase immersion cooling, and other emerging thermal management technologies.
-
Understanding heat transfer mechanisms, coolant properties, thermal resistance, heat exchanger performance, and cooling efficiency in high-density computing environments.
-
Evaluation of liquid cooling suitability based on server design, GPU thermal requirements, rack density, facility infrastructure, and maintenance considerations.
-
Assessment of liquid cooling deployment challenges involving equipment compatibility, service procedures, operational risks, and long-term reliability.
Module 4: Direct-to-Chip Cooling System Design and Engineering
-
Architecture of direct-to-chip cooling systems, including cold plates, coolant loops, manifolds, hoses, quick-disconnect couplings, and server-level distribution components.
-
Engineering of coolant flow rates, pressure differentials, temperature limits, heat loads, and thermal performance requirements for GPU and CPU cooling.
-
Selection of cold plate materials, coolant formulations, sealing technologies, piping components, and connection arrangements for reliable operation.
-
Integration of server cooling circuits with rack manifolds and facility cooling distribution systems while maintaining equipment manufacturer requirements.
Module 5: Coolant Distribution Units and Liquid Cooling Infrastructure
-
Design and operation of coolant distribution units, including pumps, heat exchangers, expansion arrangements, filtration, control valves, and monitoring instrumentation.
-
Evaluation of CDU primary and secondary loops, hydraulic separation, heat transfer interfaces, flow control, and pressure management.
-
Development of piping and manifold arrangements for distributing coolant across multiple high-density racks and AI computing clusters.
-
Application of redundancy, bypass arrangements, isolation valves, leak detection, and maintainability provisions within liquid cooling infrastructure.
Module 6: Facility Water Systems and Heat Rejection Engineering
-
Design of facility water and chilled water infrastructure supporting liquid-cooled AI racks, including pumps, chillers, cooling towers, and heat exchangers.
-
Evaluation of supply and return water temperatures, water quality, flow requirements, hydraulic balancing, and heat rejection capacity.
-
Integration of liquid cooling systems with air-cooled infrastructure, economizers, free cooling, and hybrid heat rejection arrangements.
-
Assessment of thermal operating envelopes, seasonal performance, environmental conditions, and facility-level cooling capacity constraints.
Module 7: Coolant Quality, Materials Compatibility and Leak Protection
-
Evaluation of coolant properties, including viscosity, thermal conductivity, specific heat, corrosion potential, and compatibility with system materials.
-
Identification of contamination risks involving particles, biological growth, corrosion products, incompatible fluids, and degradation of coolant quality.
-
Selection of piping materials, seals, gaskets, hoses, quick-disconnect couplings, filters, and corrosion protection measures.
-
Design of leak detection systems, containment provisions, automatic isolation strategies, inspection procedures, and liquid cooling emergency response arrangements.
Module 8: AI Data Center Electrical Power Architecture
-
Development of electrical supply architectures covering utility connections, medium-voltage distribution, transformers, generators, UPS systems, and low-voltage distribution.
-
Assessment of high-density AI rack power requirements, load profiles, electrical demand forecasting, and facility capacity planning.
-
Design of electrical redundancy strategies, including N, N+1, 2N, distributed redundant, and other appropriate power system configurations.
-
Coordination of electrical infrastructure with AI equipment deployment schedules, rack layouts, cooling requirements, and anticipated capacity expansion.
Module 9: High-Density Power Distribution and Rack-Level Electrical Integration
-
Engineering of busway systems, remote power panels, rack power distribution units, intelligent PDUs, branch circuits, and rack-level electrical connections.
-
Calculation of rack power demand, current requirements, conductor sizing, voltage drop, loading limits, and distribution capacity for high-density AI installations.
-
Evaluation of high-current power distribution arrangements, busbar technologies, connection interfaces, protective devices, and equipment compatibility.
-
Introduction to emerging high-voltage and direct-current distribution concepts for future AI data center architectures, including associated protection and safety considerations.
Module 10: UPS Systems, Battery Technologies and Power Quality
-
Selection and integration of UPS architectures supporting high-density AI loads, including modular configurations, redundancy, efficiency, and operational flexibility.
-
Assessment of battery technologies, battery monitoring, energy storage requirements, backup duration, and power continuity considerations.
-
Analysis of power quality, harmonics, transient loads, voltage regulation, power factor, and electrical disturbances affecting AI computing infrastructure.
-
Coordination of UPS systems, generators, transfer switches, electrical protection, and rack-level distribution for reliable power delivery.
Module 11: Integrated Rack Power, Cooling and Network Infrastructure
-
Development of coordinated rack layouts integrating GPU servers, high-speed networking equipment, electrical distribution, liquid cooling manifolds, and monitoring devices.
-
Engineering of rack cable management, power routing, coolant hose arrangement, quick-disconnect accessibility, airflow management, and service clearances.
-
Evaluation of rack structural loading, equipment weight distribution, vibration considerations, anchoring, containment, and installation requirements.
-
Coordination of power and cooling interfaces across AI clusters to support consistent equipment deployment, operational maintainability, and infrastructure scalability.
Module 12: Monitoring, Automation and AI Infrastructure Management
-
Integration of power meters, coolant temperature sensors, pressure transmitters, flow meters, leak detection devices, and environmental monitoring equipment.
-
Development of monitoring architectures connecting rack PDUs, CDUs, BMS, SCADA, and DCIM platforms for centralized infrastructure visibility.
-
Configuration of alarms, thresholds, operating limits, equipment status indicators, and automated notifications for abnormal power and cooling conditions.
-
Application of analytics, trend monitoring, and predictive maintenance to identify infrastructure degradation, equipment faults, and energy optimization opportunities.
Module 13: Energy Efficiency and Thermal Performance Optimization
-
Assessment of electrical and cooling energy consumption across AI server racks, UPS systems, cooling distribution equipment, and facility heat rejection systems.
-
Application of PUE, cooling system efficiency, power utilization, thermal performance, and other indicators to evaluate AI data center efficiency.
-
Optimization of coolant temperatures, pump speeds, flow distribution, cooling equipment sequencing, and heat exchanger performance.
-
Evaluation of heat recovery, free cooling, liquid cooling efficiency, and workload-aware energy management opportunities for high-density facilities.
Module 14: Integrated Engineering Design and Capacity Planning
-
Development of coordinated engineering calculations for rack power density, thermal loads, coolant flow, heat rejection, electrical distribution, and facility capacity.
-
Preparation of electrical single-line diagrams, cooling schematics, rack elevations, piping layouts, interface schedules, and infrastructure design documentation.
-
Evaluation of future AI workload growth, GPU density increases, rack expansion, power demand, cooling scalability, and phased deployment requirements.
-
Application of design reviews, interface management, engineering risk assessments, and multidisciplinary coordination across electrical, mechanical, and IT teams.
Module 15: Installation, Commissioning and Integrated Systems Testing
-
Preparation of installation and commissioning plans for liquid cooling systems, electrical distribution equipment, rack assemblies, monitoring devices, and supporting infrastructure.
-
Execution of electrical inspections, insulation resistance testing, protection verification, load testing, and rack-level power distribution validation.
-
Commissioning of CDUs, coolant loops, pumps, valves, flow sensors, pressure controls, temperature monitoring, and leak detection systems.
-
Integrated systems testing covering cooling failures, power interruptions, equipment isolation, redundancy transitions, alarms, recovery scenarios, and operational handover.
Module 16: Operations, Reliability and Capstone Integration Project
-
Development of operating procedures for AI rack infrastructure, liquid cooling systems, electrical distribution, equipment maintenance, and emergency response.
-
Application of reliability engineering, failure mode analysis, preventive maintenance, condition monitoring, and lifecycle management to critical infrastructure assets.
-
Preparation of an integrated AI-ready rack design covering server configuration, power requirements, liquid cooling connections, monitoring, and supporting facility interfaces.
-
Presentation of an implementation roadmap addressing engineering validation, commissioning, operational readiness, energy performance, capacity expansion, and long-term infrastructure resilience.
Training Approach
This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.
Tailor-Made Course
This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808
Training Venue
The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.
Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant
Certification
Participants will be issued with Upskill certificate upon completion of this course.
Airport Pickup and Accommodation
Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808
Terms of Payment:
Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.