Course Introduction
Artificial Intelligence (AI), machine learning, high-performance computing (HPC) and large-scale GPU workloads are transforming the design and engineering requirements of modern data centers. Traditional facilities designed for conventional enterprise IT may not have the electrical capacity, cooling capability, structural strength or infrastructure flexibility required by high-density AI computing environments. The AI-Ready Data Center Infrastructure Design and Engineering Training Course provides a comprehensive understanding of the engineering principles, technologies and planning strategies needed to develop data centers capable of supporting demanding AI workloads.
This course explores the relationship between AI computing requirements and critical facility infrastructure. Participants examine GPU clusters, high-density server racks, accelerated computing platforms, high-speed networking and storage systems, together with the supporting electrical and mechanical infrastructure. The programme explains how workload characteristics influence rack power density, thermal loads, network architecture, redundancy requirements and facility capacity. It also considers how infrastructure designers can translate IT performance requirements into practical architectural, electrical, mechanical and operational design specifications.
A major focus is placed on electrical infrastructure for AI-ready data centers. Participants examine utility power requirements, medium- and low-voltage distribution, transformers, switchgear, UPS systems, generators, busways, rack power distribution and intelligent monitoring. The course considers the challenges associated with high-density GPU clusters, dynamic power demand, load balancing, electrical protection and power redundancy. It also explores emerging high-voltage and direct-current distribution concepts, including their potential applications in future high-performance computing environments.
The programme provides detailed coverage of advanced cooling technologies and thermal engineering for AI infrastructure. Participants explore direct-to-chip liquid cooling, cold plates, coolant distribution units (CDUs), rear-door heat exchangers, immersion cooling and hybrid air-liquid cooling configurations. The course examines thermal load calculations, coolant distribution, flow requirements, heat rejection, leak detection and cooling redundancy. Particular attention is given to the integration of IT equipment, rack-level cooling systems and facility cooling plants to support increasingly dense computing environments.
The course also addresses architectural planning, structural engineering, network infrastructure, physical security, environmental monitoring and infrastructure resilience. Participants examine floor loading, equipment clearances, rack dimensions, cable pathways, modular data center configurations and expansion strategies. The programme considers the importance of site selection, utility availability, water resources, grid connectivity, energy efficiency and sustainability. It also highlights the need for integrated engineering design, where power, cooling, IT architecture and building systems are planned together rather than developed as isolated disciplines.
By completing this training, participants will gain the knowledge required to evaluate existing facilities, plan new AI-ready infrastructure and identify engineering requirements for high-density computing deployments. They will be better prepared to assess power and cooling capacity, develop infrastructure specifications, coordinate multidisciplinary engineering teams and evaluate future technology options. The course supports organisations seeking to build scalable, resilient and energy-conscious data centers that can accommodate evolving AI workloads and next-generation computing technologies.
Duration
5 days
Who Should Attend
This course is designed for professionals involved in data center planning, design, engineering, construction, commissioning and operation, including:
-
Data center design engineers and infrastructure architects.
-
Electrical engineers responsible for critical power systems.
-
Mechanical engineers and HVAC design specialists.
-
Data center facilities managers and operations managers.
-
AI infrastructure and high-performance computing specialists.
-
Data center project managers and engineering consultants.
-
MEP engineers involved in mission-critical facility projects.
-
Data center construction and development professionals.
-
Critical infrastructure and reliability engineers.
-
IT infrastructure architects and GPU cluster specialists.
-
Cooling system engineers and liquid cooling specialists.
-
Power distribution and energy management professionals.
-
Data center commissioning and testing engineers.
-
Technical directors and engineering supervisors.
-
Sustainability and energy efficiency professionals.
-
Professionals planning data center upgrades for AI and HPC workloads.
Course Objectives
By the end of this course, participants will be able to:
-
Explain the infrastructure requirements of AI, machine learning and high-performance computing workloads, including GPU clusters, high-density racks, accelerated computing and supporting network infrastructure.
-
Evaluate AI data center capacity requirements by analysing IT load profiles, rack power density, cooling demand, growth projections and infrastructure scalability.
-
Develop integrated electrical infrastructure concepts covering utility supplies, transformers, switchgear, UPS systems, generators, busways and intelligent rack power distribution.
-
Assess advanced cooling technologies, including direct-to-chip liquid cooling, immersion cooling, rear-door heat exchangers and hybrid air-liquid cooling systems.
-
Perform preliminary power and thermal load assessments to determine the capacity requirements of high-density computing environments and supporting facility systems.
-
Identify architectural and structural design considerations involving floor loading, equipment layouts, rack dimensions, cable pathways, cooling distribution and modular expansion.
-
Understand high-density power distribution concepts, electrical redundancy, protection coordination and emerging high-voltage and DC power architectures for AI facilities.
-
Evaluate infrastructure resilience through redundancy planning, fault tolerance, maintainability, operational risk assessment and integrated testing strategies.
-
Apply energy efficiency and sustainability principles when assessing cooling technologies, power usage, water consumption and overall facility performance.
-
Coordinate multidisciplinary design requirements and develop engineering specifications, infrastructure strategies and implementation plans for scalable AI-ready data centers.
Comprehensive Course Outline
Module 1: Fundamentals of AI-Ready Data Center Infrastructure
-
Evolution of data center infrastructure from conventional enterprise facilities to AI, machine learning and high-performance computing environments.
-
Architecture and operating requirements of GPU clusters, accelerated computing platforms, AI servers, storage systems and high-speed networking.
-
Understanding rack power density, computing intensity, thermal loads and the impact of AI workload characteristics on facility design.
-
Key components of AI-ready infrastructure, including power systems, cooling plants, network connectivity, structural facilities and monitoring platforms.
Module 2: AI Workload Assessment and Infrastructure Capacity Planning
-
Analysing AI workload requirements, GPU configurations, server specifications, computing capacity and anticipated infrastructure demand.
-
Calculating preliminary IT power loads, rack density, cooling requirements and supporting mechanical and electrical capacity.
-
Planning infrastructure capacity blocks, rack configurations, equipment deployment sequences and phased expansion strategies.
-
Evaluating future technology requirements, workload uncertainty, scalability constraints and the risks of infrastructure overdesign or undercapacity.
Module 3: Electrical Power Architecture for AI Data Centers
-
Designing utility power connections, medium-voltage systems, transformers, switchgear and low-voltage distribution for high-density computing facilities.
-
Understanding UPS configurations, backup generators, automatic transfer switches, power distribution units and rack-level electrical infrastructure.
-
Evaluating busway systems, intelligent PDUs, power monitoring, load balancing and electrical protection for high-density GPU deployments.
-
Exploring high-voltage direct-current distribution concepts, including 800 VDC architectures, and their potential engineering applications.
Module 4: Advanced Cooling and Thermal Engineering for AI Infrastructure
-
Understanding the thermal characteristics of high-performance GPUs, AI accelerators, high-density servers and intensive computing workloads.
-
Designing direct-to-chip liquid cooling systems, cold plates, coolant distribution units, manifolds and facility water circuits.
-
Evaluating immersion cooling, rear-door heat exchangers, in-row cooling and hybrid air-liquid cooling configurations.
-
Assessing cooling capacity, heat rejection, coolant temperatures, hydraulic requirements, leak detection and cooling system redundancy.
Module 5: Data Center Architecture, Structural Design and Facility Layout
-
Developing AI data center site layouts, building configurations, equipment zones and infrastructure arrangements for high-density deployments.
-
Assessing structural floor loading, rack weight, equipment anchoring, vibration considerations and space requirements for liquid cooling systems.
-
Planning electrical rooms, mechanical plant areas, server halls, cooling distribution pathways and maintenance access zones.
-
Integrating modular construction, prefabricated infrastructure modules and phased deployment strategies to support scalable development.
Module 6: Network, Storage and IT Infrastructure Engineering
-
Understanding high-speed networking requirements for distributed AI computing, GPU interconnects and large-scale model training environments.
-
Planning fiber-optic infrastructure, structured cabling, network pathways, rack connectivity and equipment distribution.
-
Evaluating storage architectures, data throughput, network latency and infrastructure requirements for AI data processing.
-
Coordinating IT equipment layouts, rack integration, cable management and physical infrastructure with power and cooling design requirements.
Module 7: Infrastructure Resilience, Redundancy and Reliability Engineering
-
Applying N, N+1, 2N and distributed redundancy concepts to electrical, mechanical and cooling infrastructure.
-
Assessing single points of failure, failure domains, equipment maintainability and operational resilience in AI data centers.
-
Developing integrated power and cooling failure response strategies, isolation procedures and infrastructure recovery arrangements.
-
Evaluating reliability engineering, fault tolerance, risk assessment, equipment lifecycle planning and critical infrastructure availability.
Module 8: Intelligent Monitoring, Automation and Infrastructure Management
-
Integrating Building Management Systems (BMS), Data Center Infrastructure Management (DCIM) and intelligent equipment monitoring platforms.
-
Monitoring electrical loads, rack power consumption, cooling performance, coolant conditions and equipment operating parameters.
-
Applying automated control systems, predictive analytics and condition monitoring to improve infrastructure performance.
-
Establishing alarms, operational dashboards, capacity reports and integrated monitoring procedures for high-density computing facilities.
Module 9: Energy Efficiency, Sustainability and Resource Optimisation
-
Evaluating Power Usage Effectiveness (PUE), cooling efficiency, energy consumption and other infrastructure performance indicators.
-
Applying free cooling, economization, heat recovery, liquid cooling and other energy-efficient technologies where site conditions permit.
-
Assessing water consumption, cooling system water efficiency, environmental impact and sustainable facility operating strategies.
-
Integrating renewable energy, grid interaction, energy storage and demand management into long-term AI data center planning.
Module 10: Engineering Standards, Commissioning and Future Infrastructure Development
-
Understanding relevant engineering standards, industry guidance, equipment specifications and design requirements for mission-critical facilities.
-
Developing engineering design documentation, technical specifications, equipment schedules and multidisciplinary design coordination procedures.
-
Planning factory acceptance testing, site acceptance testing, integrated systems testing and commissioning of electrical and mechanical infrastructure.
-
Evaluating emerging AI infrastructure technologies, modular facilities, next-generation cooling systems and long-term data center development strategies.
Training Approach
This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.
Tailor-Made Course
This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808
Training Venue
The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.
Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant
Certification
Participants will be issued with Upskill certificate upon completion of this course.
Airport Pickup and Accommodation
Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808
Terms of Payment:
Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.