Course Introduction
The Advanced Data Center Infrastructure Modeling, Simulation and Performance Optimization Training Course is designed to equip professionals with advanced technical knowledge and practical skills for developing, analyzing, and optimizing complex data center infrastructure models. It focuses on using engineering models, simulation techniques, analytical tools, and performance evaluation methodologies to improve the reliability, efficiency, scalability, and resilience of modern data center facilities.
Data centers operate as highly interconnected environments where electrical power, cooling systems, information and communications technology (ICT), physical infrastructure, and operational processes must function together. Changes in one subsystem can influence the performance of others, making integrated infrastructure modeling essential. This course examines how engineering models can represent these interactions and help professionals assess system behavior under normal, peak-load, contingency, and abnormal operating conditions.
Participants will explore advanced simulation approaches for electrical distribution networks, backup power systems, cooling infrastructure, airflow management, thermal behavior, network capacity, and facility energy consumption. The course explains how simulation models can be developed from engineering drawings, equipment specifications, operational measurements, building management systems, and data center infrastructure management information. Emphasis is placed on model accuracy, validation, assumptions, boundary conditions, and the interpretation of simulation results.
A major component of the programme addresses data center performance optimization through engineering analysis and evidence-based decision-making. Participants will examine methods for identifying infrastructure bottlenecks, evaluating equipment utilization, improving power usage effectiveness (PUE), optimizing cooling efficiency, balancing IT loads, and reducing operational losses. The course also explores how computational modeling can support capacity planning, infrastructure upgrades, equipment replacement, and the assessment of emerging technologies.
The programme further considers the application of digital twins, computational fluid dynamics, predictive analytics, artificial intelligence, and machine learning in data center engineering. Participants will learn how these technologies can support real-time performance monitoring, predictive maintenance, energy optimization, and scenario-based planning. Particular attention is given to the opportunities and limitations of advanced modeling technologies, including data quality, model governance, cybersecurity, and the need to maintain alignment between digital models and physical infrastructure.
By the end of the course, participants will be better equipped to develop and interpret infrastructure simulation models, evaluate alternative engineering configurations, quantify operational performance, and recommend practical optimization measures. The knowledge gained will support improved engineering decisions, more efficient resource utilization, stronger operational resilience, and the long-term performance of mission-critical data center facilities.
Duration
10 days
Who Should Attend
-
Data center design and infrastructure engineers responsible for developing and evaluating facility engineering solutions.
-
Electrical engineers involved in power distribution, backup generation, UPS systems, and electrical infrastructure optimization.
-
Mechanical and HVAC engineers responsible for cooling systems, airflow management, and thermal performance.
-
Data center facilities managers overseeing infrastructure availability, efficiency, maintenance, and operational performance.
-
Data center operations managers responsible for monitoring and improving critical infrastructure performance.
-
ICT infrastructure architects involved in capacity planning, IT load distribution, and technology integration.
-
Building services engineers seeking advanced simulation and modeling capabilities for mission-critical facilities.
-
Energy managers responsible for improving energy efficiency and reducing data center operating costs.
-
Commissioning engineers involved in functional testing, integrated systems testing, and performance verification.
-
Engineering consultants providing data center design reviews, modeling, simulation, and optimization services.
-
Digital transformation specialists implementing digital twins, analytics, and intelligent infrastructure management systems.
-
Technical project managers overseeing data center construction, expansion, modernization, and infrastructure upgrades.
-
Reliability engineers responsible for assessing system availability, redundancy, and operational resilience.
-
Sustainability and environmental professionals involved in data center energy management and carbon reduction initiatives.
Course Objectives
By the end of this course, participants will be able to:
• Explain the principles, methodologies, and applications of advanced infrastructure modeling and simulation in modern data center environments, including their role in engineering design and operational decision-making.
• Develop integrated data center infrastructure models that represent electrical, mechanical, cooling, ICT, and facility management systems and their interdependencies under different operating conditions.
• Apply engineering simulation techniques to evaluate electrical power distribution, UPS configurations, generator performance, load sharing, and critical power system reliability.
• Analyze airflow patterns, heat transfer, cooling distribution, and thermal behavior using computational methods to identify cooling inefficiencies and improve environmental control.
• Evaluate data center infrastructure performance using appropriate indicators, including PUE, cooling efficiency, energy consumption, equipment utilization, availability, and operational resilience.
• Apply computational fluid dynamics and thermal modeling techniques to assess airflow distribution, temperature variations, hot spots, and alternative cooling configurations.
• Develop and validate simulation models using engineering drawings, equipment specifications, sensor readings, operational records, and historical infrastructure performance data.
• Conduct scenario-based simulations to evaluate peak demand, equipment failure, maintenance conditions, system contingencies, future capacity requirements, and infrastructure expansion options.
• Identify infrastructure bottlenecks, underperforming equipment, energy losses, and operational inefficiencies through systematic simulation analysis and performance benchmarking.
• Apply optimization techniques to improve electrical and mechanical system efficiency, cooling performance, equipment utilization, and overall data center operating costs.
• Assess the application of digital twins, artificial intelligence, machine learning, and predictive analytics in improving data center infrastructure monitoring and optimization.
• Prepare technical simulation reports, performance assessments, and evidence-based recommendations that support infrastructure investment, operational improvements, and long-term facility reliability.
Comprehensive Course Outline
Module 1: Fundamentals of Data Center Infrastructure Modeling and Simulation
-
Principles of engineering modeling and simulation and their applications in mission-critical data center infrastructure planning, design, and operations.
-
Overview of integrated data center systems, including electrical distribution, mechanical cooling, ICT infrastructure, and facility management.
-
Types of infrastructure models, including analytical, numerical, statistical, dynamic, and discrete-event simulation models.
-
Modeling objectives, assumptions, system boundaries, input parameters, constraints, and expected performance outputs.
Module 2: Data Center Infrastructure Architecture and System Interdependencies
-
Analysis of data center architecture, infrastructure topology, equipment configurations, and relationships between critical facility systems.
-
Modeling dependencies between IT loads, electrical distribution, cooling demand, environmental conditions, and facility operating parameters.
-
Evaluation of redundancy configurations, including N, N+1, 2N, and distributed redundant infrastructure arrangements.
-
Identification of critical infrastructure dependencies, single points of failure, shared resources, and potential performance constraints.
Module 3: Engineering Data Collection and Model Development
-
Collection and interpretation of engineering drawings, equipment schedules, technical specifications, asset registers, and infrastructure configuration data.
-
Development of simulation input datasets using operational measurements, sensor information, historical records, and equipment performance curves.
-
Definition of model assumptions, boundary conditions, initial conditions, operating limits, and equipment characteristics.
-
Application of data cleaning, parameter estimation, data normalization, and quality assurance techniques to improve model reliability.
Module 4: Electrical Infrastructure Modeling and Simulation
-
Modeling of electrical distribution networks, transformers, switchgear, busbars, protective devices, and critical power pathways.
-
Simulation of UPS systems, battery storage, generators, automatic transfer switches, and emergency power configurations.
-
Analysis of electrical load flow, voltage stability, short-circuit conditions, power quality, and system loading.
-
Evaluation of electrical redundancy, equipment failure scenarios, load transfer arrangements, and alternative power system configurations.
Module 5: Mechanical Systems and Cooling Infrastructure Simulation
-
Modeling of chillers, cooling towers, pumps, heat exchangers, computer room air conditioning, and computer room air handling systems.
-
Simulation of chilled-water distribution, cooling capacity, hydraulic performance, and mechanical system operating conditions.
-
Assessment of cooling equipment efficiency, part-load behavior, redundancy, and performance under varying IT demand.
-
Evaluation of alternative cooling architectures, including direct expansion, chilled-water, liquid cooling, and hybrid cooling systems.
Module 6: Computational Fluid Dynamics and Thermal Modeling
-
Fundamentals of computational fluid dynamics and its application to data center airflow and heat transfer analysis.
-
Development of thermal models to evaluate rack inlet temperatures, hot spots, cold aisles, hot aisles, and air recirculation.
-
Simulation of airflow distribution, pressure differentials, containment arrangements, and cooling supply configurations.
-
Interpretation of CFD outputs to identify thermal risks, improve airflow management, and optimize cooling infrastructure design.
Module 7: IT Infrastructure Load and Capacity Modeling
-
Modeling of server, storage, networking, and other IT equipment loads to determine infrastructure demand and utilization patterns.
-
Analysis of rack power density, equipment diversity, workload distribution, and changing computational requirements.
-
Simulation of IT capacity growth, workload consolidation, virtualization, and high-density computing environments.
-
Assessment of the infrastructure implications of artificial intelligence workloads, GPU clusters, and high-performance computing facilities.
Module 8: Data Center Energy Modeling and Efficiency Analysis
-
Modeling of data center energy consumption across IT equipment, electrical losses, cooling systems, lighting, and auxiliary infrastructure.
-
Calculation and interpretation of PUE, energy reuse effectiveness, cooling efficiency, and other relevant performance indicators.
-
Simulation of energy-saving strategies, including temperature set-point adjustments, variable-speed equipment, and cooling optimization.
-
Evaluation of renewable energy integration, battery energy storage, waste heat recovery, and low-carbon infrastructure alternatives.
Module 9: Dynamic Simulation and Operational Scenario Analysis
-
Development of time-dependent models to assess infrastructure behavior during changing workloads and environmental conditions.
-
Simulation of peak demand, equipment start-up, shutdown, load transfer, maintenance, and emergency operating conditions.
-
Analysis of cascading failures, system recovery behavior, and the impact of component outages on critical services.
-
Use of what-if analysis and sensitivity testing to compare alternative operational strategies and engineering configurations.
Module 10: Model Validation, Calibration and Verification
-
Principles of model verification, validation, calibration, and performance testing for engineering simulation applications.
-
Comparison of simulated outputs with measured operating data, commissioning results, and established equipment performance characteristics.
-
Identification and management of modeling uncertainty, inaccurate assumptions, missing data, and parameter sensitivity.
-
Documentation of model limitations, validation criteria, acceptance thresholds, and engineering confidence levels.
Module 11: Infrastructure Performance Optimization Techniques
-
Application of optimization methodologies to improve electrical distribution efficiency, cooling performance, and infrastructure utilization.
-
Identification of bottlenecks, equipment oversizing, underutilized capacity, energy losses, and inefficient operating configurations.
-
Application of multi-objective optimization to balance energy consumption, reliability, availability, cost, and environmental performance.
-
Evaluation of optimization alternatives using performance comparisons, engineering constraints, lifecycle costs, and operational risk assessments.
Module 12: Digital Twins and Intelligent Infrastructure Modeling
-
Principles and architecture of digital twins and their application to data center design, commissioning, and operational management.
-
Integration of building management systems, data center infrastructure management platforms, IoT sensors, and engineering simulation models.
-
Development of real-time infrastructure representations using operational telemetry, equipment status, and performance information.
-
Evaluation of digital twin applications for predictive maintenance, capacity forecasting, fault detection, and infrastructure optimization.
Module 13: Artificial Intelligence, Machine Learning and Predictive Analytics
-
Application of machine learning techniques to analyze infrastructure performance, identify abnormal behavior, and detect emerging faults.
-
Use of predictive analytics to forecast power demand, cooling requirements, equipment degradation, and future capacity needs.
-
Evaluation of AI-supported cooling optimization, automated control strategies, and intelligent energy management applications.
-
Assessment of AI model accuracy, data governance, explainability, cybersecurity, and human oversight in mission-critical environments.
Module 14: Reliability, Resilience and Risk-Based Simulation
-
Application of reliability engineering principles to model equipment failure rates, system availability, and infrastructure resilience.
-
Simulation of redundancy failures, maintenance scenarios, common-mode failures, and loss of critical infrastructure components.
-
Use of fault tree analysis, failure mode and effects analysis, and reliability block diagrams in performance assessment.
-
Evaluation of recovery strategies, resilience improvements, risk mitigation measures, and operational continuity requirements.
Module 15: Simulation Software, Data Integration and Technical Reporting
-
Overview of engineering modeling and simulation software used for electrical systems, mechanical infrastructure, CFD, and energy analysis.
-
Integration of simulation platforms with BIM, CAD, DCIM, BMS, asset management, and operational monitoring systems.
-
Development of simulation workflows, model libraries, performance dashboards, and structured engineering analysis processes.
-
Preparation of technical reports, model documentation, performance visualizations, recommendations, and management presentations.
Module 16: Advanced Applications, Emerging Technologies and Practical Optimization Project
-
Simulation of liquid cooling, immersion cooling, high-density computing, modular data centers, and next-generation infrastructure architectures.
-
Evaluation of microgrids, renewable energy, battery storage, grid interaction, and energy flexibility in data center operations.
-
Assessment of emerging challenges involving AI-driven demand growth, sustainability requirements, water consumption, and infrastructure scalability.
-
Development of an integrated data center simulation and optimization project, including model evaluation, scenario testing, and improvement recommendations.
Training Approach
This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.
Tailor-Made Course
This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808
Training Venue
The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.
Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant
Certification
Participants will be issued with Upskill certificate upon completion of this course.
Airport Pickup and Accommodation
Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808
Terms of Payment:
Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.