Advanced Data Center Direct-to-Chip and Immersion Cooling Technologies Training Course

Master direct-to-chip and immersion cooling technologies for next-generation data centers. Learn cold plate engineering, dielectric fluid management, CDU design, hydraulic integration, commissioning, maintenance, and AI thermal optimization.
Duration: 10 Days Classroom & Online In-House Available Certificate on Completion

Training Registration & Schedule

Compare training options, fees and available dates, then register for your preferred session.

Online Training Registration

Training ModePlatformDurationFee per ParticipantRegistration
LIVE ONLINEInstructor-led training Zoom / Google MeetAttend from anywhere 10 days USD 1,740 Register Online →

Classroom / On-site Training Schedule

15 upcoming sessions

Swipe horizontally to see all columns →

Training DatesLocationTraining ModeFee per ParticipantRegistration
07 Dec 2026 – 18 Dec 202610 training days Mombasa CLASSROOM USD 3,400 Register Now →
21 Dec 2026 – 01 Jan 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
18 Jan 2027 – 29 Jan 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
18 Jan 2027 – 29 Jan 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
15 Feb 2027 – 26 Feb 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
15 Feb 2027 – 26 Feb 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
15 Mar 2027 – 26 Mar 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
15 Mar 2027 – 26 Mar 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
19 Apr 2027 – 30 Apr 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
19 Apr 2027 – 30 Apr 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
17 May 2027 – 28 May 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
17 May 2027 – 28 May 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
21 Jun 2027 – 02 Jul 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
21 Jun 2027 – 02 Jul 202710 training days Mombasa CLASSROOM USD 3,400 Register Now →
19 Jul 2027 – 30 Jul 202710 training days Nairobi CLASSROOM USD 2,900 Register Now →
Need registration assistance? Contact training@upskilldevelopment.com for training dates, invoices and invitation letters.

Nairobi, Kenya Classroom/On-site Training Schedule

Course Date Location Fee Enroll
21/12/2026 to 01/01/2027 Nairobi 2,900 USD Register
18/01/2027 to 29/01/2027 Nairobi 2,900 USD Register
15/02/2027 to 26/02/2027 Nairobi 2,900 USD Register
15/03/2027 to 26/03/2027 Nairobi 2,900 USD Register
19/04/2027 to 30/04/2027 Nairobi 2,900 USD Register
17/05/2027 to 28/05/2027 Nairobi 2,900 USD Register
21/06/2027 to 02/07/2027 Nairobi 2,900 USD Register
19/07/2027 to 30/07/2027 Nairobi 2,900 USD Register
16/08/2027 to 27/08/2027 Nairobi 2,900 USD Register
20/09/2027 to 01/10/2027 Nairobi 2,900 USD Register
18/10/2027 to 29/10/2027 Nairobi 2,900 USD Register
15/11/2027 to 26/11/2027 Nairobi 2,900 USD Register
20/12/2027 to 31/12/2027 Nairobi 2,900 USD Register

Mombasa, Kenya Classroom/On-site Training Schedule

Course Date Location Fee Enroll
07/12/2026 to 18/12/2026 Mombasa 3,400 USD Register
18/01/2027 to 29/01/2027 Mombasa 3,400 USD Register
15/02/2027 to 26/02/2027 Mombasa 3,400 USD Register
15/03/2027 to 26/03/2027 Mombasa 3,400 USD Register
19/04/2027 to 30/04/2027 Mombasa 3,400 USD Register
17/05/2027 to 28/05/2027 Mombasa 3,400 USD Register
21/06/2027 to 02/07/2027 Mombasa 3,400 USD Register
19/07/2027 to 30/07/2027 Mombasa 3,400 USD Register
16/08/2027 to 27/08/2027 Mombasa 3,400 USD Register
20/09/2027 to 01/10/2027 Mombasa 3,400 USD Register
18/10/2027 to 29/10/2027 Mombasa 3,400 USD Register
15/11/2027 to 26/11/2027 Mombasa 3,400 USD Register
20/12/2027 to 31/12/2027 Mombasa 3,400 USD Register

Kigali, Rwanda Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Dubai, UAE Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Dar es Salaam, Tanzania Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Kampala, Uganda Classroom/On-site Training Schedule

Course Date Location Fee Enroll

Course Introduction

The Advanced Data Center Direct-to-Chip and Immersion Cooling Technologies Training Course provides specialized technical knowledge and practical engineering methodologies for designing, implementing, operating, and optimizing advanced liquid cooling solutions in modern data centers. The rapid growth of artificial intelligence, machine learning, high-performance computing, and GPU-intensive workloads has significantly increased processor heat generation and rack power density. Traditional air cooling systems are increasingly challenged by these thermal demands, making direct-to-chip and immersion cooling important technologies for next-generation computing infrastructure. This course examines the engineering principles, system architectures, equipment requirements, installation procedures, and operational considerations associated with these advanced cooling technologies.

The program begins by examining the thermal characteristics of high-density computing equipment and the engineering requirements for removing heat directly from electronic components. Participants explore heat transfer mechanisms, thermal resistance, coolant properties, heat flux, flow distribution, and the relationship between processor power consumption and cooling performance. Particular attention is given to the thermal requirements of GPUs, CPUs, accelerators, memory modules, and other high-performance components. The course explains how cooling system design must account for component temperature limits, coolant supply conditions, pressure losses, flow requirements, rack configurations, and the dynamic operating characteristics of modern computing workloads.

A major component of the training focuses on direct-to-chip cooling technologies, including cold plates, coolant distribution units, rack manifolds, secondary fluid networks, and heat exchangers. Participants examine the design and operation of cold plate assemblies, thermal interface materials, coolant channels, quick-disconnect connections, pumps, valves, and monitoring instruments. The program explores hydraulic calculations, coolant selection, piping arrangements, pressure management, temperature control, and integration with facility chilled-water infrastructure. It also addresses practical engineering challenges such as maintaining uniform coolant distribution, controlling leakage risks, preventing contamination, managing corrosion, and ensuring compatibility between liquid cooling systems and IT equipment manufacturers' specifications.

The course further examines single-phase and two-phase immersion cooling technologies, which involve placing compatible electronic equipment within specialized dielectric fluids. Participants investigate the physical principles of immersion cooling, fluid circulation, boiling and condensation processes, heat exchanger arrangements, tank configurations, and thermal management requirements. The program considers dielectric fluid characteristics, material compatibility, fluid stability, filtration, vapor management, condensation control, and equipment handling procedures. It also evaluates the advantages and limitations of immersion cooling in comparison with direct-to-chip and conventional air cooling, particularly in applications involving high-density computing, specialized server platforms, and large-scale AI infrastructure.

Installation, commissioning, operation, and maintenance are addressed through practical engineering procedures and reliability-focused methodologies. Participants explore equipment installation, piping connections, tank preparation, coolant filling, system flushing, leak testing, pressure testing, functional verification, and thermal performance evaluation. The training also examines preventive maintenance, coolant quality monitoring, filtration management, fluid sampling, pump inspections, heat exchanger cleaning, and troubleshooting of abnormal operating conditions. Special attention is given to safe handling of dielectric fluids, prevention of coolant contamination, maintenance access, equipment isolation, and emergency response procedures for leakage, circulation failure, and thermal excursions.

By completing this course, participants will be better equipped to evaluate, design, implement, and manage direct-to-chip and immersion cooling systems for advanced data center environments. The program combines thermal engineering, fluid mechanics, mechanical system design, equipment integration, operational management, and reliability optimization. Participants gain practical approaches for supporting higher rack densities, improving cooling effectiveness, managing complex liquid cooling infrastructure, and preparing facilities for future AI and high-performance computing requirements. The knowledge acquired supports informed technology selection, effective project execution, and long-term operational sustainability.

Duration

10 days

Who Should Attend

  • Data center mechanical engineers responsible for designing and implementing advanced liquid cooling systems.

  • HVAC engineers involved in integrating direct-to-chip and immersion cooling with facility cooling infrastructure.

  • Liquid cooling system designers responsible for cold plates, coolant distribution units, manifolds, and fluid networks.

  • Data center facilities managers overseeing advanced cooling operations, equipment reliability, and thermal performance.

  • AI and high-performance computing infrastructure engineers managing high-density GPU and accelerator installations.

  • Thermal engineers responsible for heat transfer analysis, thermal resistance calculations, and cooling performance evaluation.

  • Mechanical project managers coordinating liquid cooling installation, integration, commissioning, and infrastructure upgrades.

  • Commissioning engineers responsible for validating direct-to-chip and immersion cooling system performance.

  • Operations engineers managing coolant circulation, temperature control, filtration, pumps, and heat exchangers.

  • Maintenance technicians responsible for servicing liquid cooling equipment and diagnosing mechanical system problems.

  • Reliability engineers evaluating cooling redundancy, equipment failure risks, and operational resilience.

  • Engineering consultants developing next-generation thermal management solutions for hyperscale and colocation facilities.

  • Equipment manufacturers and technical specialists involved in liquid cooling products, dielectric fluids, and cooling components.

  • Energy and sustainability professionals evaluating advanced cooling efficiency, heat recovery, and facility energy optimization.

Course Objectives

  • Understand the engineering principles of direct-to-chip and immersion cooling, including heat transfer, fluid dynamics, thermal resistance, and component-level heat removal.

  • Evaluate single-phase and two-phase immersion cooling technologies and determine their suitability for different high-density data center applications.

  • Analyze the thermal characteristics of GPUs, CPUs, accelerators, and other high-performance computing components to establish appropriate cooling requirements.

  • Design direct-to-chip cooling arrangements incorporating cold plates, coolant distribution units, manifolds, pumps, heat exchangers, and associated piping networks.

  • Calculate coolant flow rates, temperature differentials, pressure losses, heat transfer capacity, and hydraulic operating parameters for advanced cooling systems.

  • Assess dielectric fluids and water-based coolants according to thermal properties, electrical characteristics, chemical stability, and material compatibility.

  • Integrate direct-to-chip and immersion cooling systems with facility chilled-water networks, heat rejection equipment, and centralized mechanical infrastructure.

  • Apply installation procedures covering equipment positioning, pipework, tank preparation, coolant filling, flushing, leak detection, and pressure testing.

  • Execute commissioning and performance verification procedures to confirm thermal effectiveness, hydraulic stability, fluid quality, and system functionality.

  • Establish operational monitoring strategies for coolant temperature, pressure, flow rate, fluid condition, equipment alarms, and thermal performance.

  • Diagnose liquid cooling problems involving leakage, contamination, corrosion, inadequate circulation, heat exchanger degradation, and abnormal component temperatures.

  • Develop maintenance and optimization strategies that improve cooling reliability, energy efficiency, operational safety, and long-term infrastructure scalability.

Comprehensive Course Outline

Module 1: Advanced Thermal Management Fundamentals for Data Centers

  • Principles of heat generation in modern computing equipment, including CPUs, GPUs, accelerators, memory modules, networking components, and high-performance server assemblies.

  • Heat transfer mechanisms involving conduction, convection, thermal resistance, heat flux, specific heat capacity, and temperature gradients in liquid cooling applications.

  • Relationship between IT power consumption, component-level thermal output, rack power density, and cooling capacity requirements in advanced data center environments.

  • Thermal design considerations involving processor junction temperatures, component operating limits, coolant temperatures, airflow interaction, and equipment reliability.

Module 2: Direct-to-Chip Cooling Architecture and Engineering Principles

  • Fundamentals of direct-to-chip cooling systems and their application in removing heat from processors, GPUs, accelerators, and other high-power electronic components.

  • Architecture of direct-to-chip installations, including cold plates, coolant distribution units, rack manifolds, secondary loops, and facility water connections.

  • Engineering evaluation of cooling capacity, heat transfer effectiveness, component thermal resistance, coolant flow distribution, and hydraulic operating conditions.

  • Assessment of direct-to-chip cooling advantages and limitations in comparison with traditional air cooling and other advanced liquid cooling technologies.

Module 3: Cold Plate Design, Selection and Thermal Performance

  • Design and operating principles of liquid-cooled cold plates, including internal channels, heat transfer surfaces, material selection, and component contact arrangements.

  • Evaluation of cold plate thermal resistance, pressure drop, coolant flow characteristics, heat transfer coefficient, and performance under variable processor loads.

  • Selection of thermal interface materials, mounting mechanisms, connection arrangements, and sealing components to maintain reliable component-level thermal contact.

  • Analysis of cold plate compatibility with GPU and CPU packages, server manufacturers' specifications, mechanical tolerances, and operating temperature limits.

Module 4: Coolant Distribution Units and Fluid Circulation Systems

  • Design and operation of coolant distribution units incorporating pumps, heat exchangers, filtration equipment, control valves, sensors, and system protection devices.

  • Comparison of in-row, in-rack, and centralized CDU configurations according to cooling capacity, redundancy, installation space, and maintenance accessibility.

  • Hydraulic evaluation of pump performance, flow rates, pressure differentials, coolant distribution, and automatic flow regulation across multiple server racks.

  • Development of CDU control strategies for temperature regulation, variable-speed pumping, pressure management, alarm generation, and equipment changeover.

Module 5: Hydraulic Design, Piping Networks and Manifold Engineering

  • Design of primary and secondary coolant circuits, including piping layouts, branch connections, flow balancing, pressure loss calculations, and distribution arrangements.

  • Engineering selection of pipe materials, flexible hoses, quick-disconnect couplings, manifolds, valves, seals, and mechanical support systems.

  • Assessment of coolant velocity, Reynolds number, friction losses, pump head requirements, thermal expansion, and hydraulic stability under changing operating conditions.

  • Prevention of uneven coolant distribution, excessive pressure drop, air entrapment, vibration, and mechanical stress within liquid cooling networks.

Module 6: Single-Phase Immersion Cooling Technologies

  • Fundamentals of single-phase immersion cooling, including dielectric fluid circulation, heat absorption, tank configurations, and external heat exchanger arrangements.

  • Engineering design of immersion tanks, server racks, fluid circulation systems, filtration units, pumps, and thermal monitoring equipment.

  • Evaluation of dielectric fluid characteristics, including thermal conductivity, viscosity, specific heat capacity, dielectric strength, and chemical stability.

  • Assessment of server compatibility, component immersion requirements, equipment handling, fluid maintenance, and operating procedures for single-phase systems.

Module 7: Two-Phase Immersion Cooling Technologies

  • Thermodynamic principles of two-phase immersion cooling, including fluid boiling, latent heat absorption, vapor generation, and condensation-based heat rejection.

  • Design and operation of two-phase immersion tanks, condensation coils, vapor management arrangements, heat exchangers, and associated fluid containment systems.

  • Evaluation of dielectric fluid boiling characteristics, saturation temperatures, vapor pressure, thermal performance, and compatibility with immersed electronic equipment.

  • Assessment of operational risks involving fluid loss, condensation inefficiency, containment integrity, environmental conditions, and specialized maintenance requirements.

Module 8: Dielectric Fluids, Coolant Chemistry and Material Compatibility

  • Comparison of dielectric immersion fluids and water-based direct-to-chip coolants according to thermal performance, chemical stability, electrical properties, and application requirements.

  • Assessment of fluid compatibility with metals, polymers, elastomers, seals, coatings, electronic components, and piping materials used in liquid cooling installations.

  • Management of coolant degradation, contamination, corrosion, oxidation, suspended particles, moisture ingress, and other conditions affecting fluid performance.

  • Development of fluid sampling, laboratory testing, filtration, replacement, storage, handling, and quality assurance procedures for long-term system reliability.

Module 9: Integration with Data Center HVAC and Heat Rejection Systems

  • Integration of direct-to-chip and immersion cooling installations with chilled-water systems, cooling plants, dry coolers, and facility heat rejection infrastructure.

  • Design of heat exchanger interfaces, primary and secondary cooling loops, hydraulic separation, temperature control, and fluid circulation arrangements.

  • Assessment of facility cooling capacity, return water temperatures, heat rejection requirements, ambient operating conditions, and system expansion requirements.

  • Evaluation of warm-water cooling, free cooling opportunities, heat recovery, and alternative heat rejection arrangements for energy-efficient operations.

Module 10: Installation Procedures and Liquid Cooling System Integration

  • Preparation of engineering drawings, equipment layouts, installation method statements, material specifications, and mechanical coordination plans.

  • Installation of cold plates, CDUs, manifolds, pumps, immersion tanks, heat exchangers, piping systems, sensors, and associated mechanical equipment.

  • Execution of piping fabrication, connection assembly, pressure testing, flushing, cleaning, coolant filling, venting, and system leak verification.

  • Coordination of mechanical installation with server manufacturers, IT infrastructure teams, electrical engineers, commissioning personnel, and data center operations staff.

Module 11: Commissioning and Thermal Performance Verification

  • Development of commissioning plans, inspection procedures, test scripts, acceptance criteria, and performance verification documentation for advanced liquid cooling systems.

  • Execution of pre-commissioning activities, including equipment inspection, system cleaning, pressure testing, coolant preparation, filling, and air removal.

  • Functional testing of pumps, heat exchangers, CDUs, valves, sensors, leak detection systems, temperature controls, and operational alarms.

  • Verification of coolant flow, pressure stability, supply and return temperatures, thermal resistance, cooling capacity, and performance under representative IT loads.

Module 12: Operation, Control Systems and Intelligent Monitoring

  • Development of operating procedures for direct-to-chip and immersion cooling equipment under normal, standby, maintenance, and abnormal operating conditions.

  • Monitoring of coolant temperature, pressure, circulation rates, fluid quality, pump operation, heat exchanger effectiveness, and thermal performance indicators.

  • Integration of liquid cooling controls with building management systems, data center infrastructure management platforms, and server-level monitoring interfaces.

  • Application of intelligent monitoring, automated control, alarm prioritization, operating trends, and predictive analytics to improve system visibility and operational stability.

Module 13: Preventive Maintenance and Equipment Reliability Management

  • Development of preventive maintenance schedules for cold plates, coolant distribution units, pumps, manifolds, immersion tanks, heat exchangers, and fluid distribution components.

  • Inspection and maintenance of hoses, quick-disconnect connections, seals, valves, filtration assemblies, sensors, and other components susceptible to leakage or degradation.

  • Management of coolant quality through sampling, filtration, laboratory analysis, contamination monitoring, and controlled fluid replacement procedures.

  • Application of reliability-centered maintenance, equipment condition monitoring, spare parts planning, and maintenance documentation to improve long-term cooling availability.

Module 14: Troubleshooting, Leakage Management and Emergency Response

  • Identification of direct-to-chip cooling failures involving inadequate coolant flow, blocked cold plates, pump malfunction, temperature instability, and hydraulic imbalance.

  • Diagnosis of immersion cooling problems involving dielectric fluid degradation, contamination, abnormal fluid levels, condensation issues, and reduced heat transfer performance.

  • Development of emergency procedures for coolant leakage, CDU failure, loss of circulation, equipment overheating, fluid spills, and cooling system isolation.

  • Application of root cause analysis, corrective maintenance, equipment recovery verification, incident reporting, and operational risk reduction techniques.

Module 15: Energy Efficiency, Thermal Optimization and Sustainability

  • Evaluation of liquid cooling energy consumption, pump power requirements, heat exchanger efficiency, coolant temperature differentials, and overall cooling system performance.

  • Optimization of coolant supply temperatures, pump operating speeds, hydraulic balance, heat rejection arrangements, and cooling equipment control strategies.

  • Assessment of liquid cooling opportunities for reducing mechanical energy consumption, improving PUE, and supporting higher data center computing densities.

  • Examination of heat recovery, warm-water cooling, water consumption, fluid lifecycle management, and environmental considerations associated with advanced cooling technologies.

Module 16: Advanced Applications, Industry Case Studies and Future Developments

  • Evaluation of direct-to-chip and immersion cooling requirements for hyperscale data centers, AI training clusters, GPU platforms, and high-performance computing installations.

  • Analysis of practical deployment challenges involving server compatibility, rack integration, coolant distribution, maintenance access, fluid selection, and operational readiness.

  • Examination of emerging developments in two-phase cooling, advanced cold plate materials, intelligent CDUs, automated leak detection, and next-generation dielectric fluids.

  • Development of future-ready cooling strategies combining thermal engineering, system integration, reliability planning, energy optimization, and scalable infrastructure design.

Training Approach

This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.

Tailor-Made Course

This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808

Training Venue 

The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.

Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant

Certification

Participants will be issued with Upskill certificate upon completion of this course.

Airport Pickup and Accommodation

Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808

Terms of Payment:

Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.

Choose Your Training Format

Attend a scheduled session or request a customized programme for your organization.

Classroom Training

Attend instructor-led training at one of our scheduled training locations.

Live Online Training

Join interactive instructor-led sessions remotely from your office or home.

In-House Training

Customize the course content, dates and delivery for your team or organization.

Certification

Participants who successfully complete the programme receive a Certificate of Completion from Upskill Development Institute.

Request Course Information

Need a Tailor-Made Programme?

We can customize the course content, duration, schedule and delivery format to match your organization's objectives.

Dates & Fees Enquire Now

Organizations we've served

Some of Our Recent Clients

We support professional development and institutional capacity building for organizations across a wide range of sectors. Explore a selection of organizations featured in our client portfolio.

SNV logoSNV
National Communications Authority logoNational Communications Authority
Masinde Muliro University of Science and Technology logoMasinde Muliro University of Science and Technology
Kenya Medical Research Institute logoKenya Medical Research Institute
Save Lamu logoSave Lamu
UNICEF logoUNICEF
Fairtrade Africa logoFairtrade Africa
World Agroforestry (ICRAF) logoWorld Agroforestry (ICRAF)
CPI logoCPI
Food and Agriculture Organization (FAO) logoFood and Agriculture Organization (FAO)
University of Southampton logoUniversity of Southampton
Ngali Holdings logoNgali Holdings
STOPAIDS logoSTOPAIDS
International Fertilizer Development Center (IFDC) logoInternational Fertilizer Development Center (IFDC)
Wide Communications logoWide Communications

Learn. Apply. Grow.

Build skills that make a difference at work

Upskill Development Institute offers practical professional training, customized group programmes and flexible learning options to help individuals and organizations strengthen performance.

Chat with us on WhatsApp