Course Introduction
The increasing demand for cloud computing, artificial intelligence, high-performance computing, and digital infrastructure has significantly increased the cooling requirements of modern data centers. Chiller plants play a critical role in maintaining the temperature stability, equipment availability, and operational resilience of mission-critical facilities. The Advanced Data Center Chiller Plant Design, Cooling Distribution and Energy Efficiency Training Course provides comprehensive engineering knowledge and practical methodologies for designing, operating, maintaining, and optimizing chilled-water infrastructure in conventional and high-density data center environments.
This course examines the engineering principles governing chiller plant architecture, cooling capacity calculations, equipment selection, hydraulic configurations, and chilled-water distribution. Participants explore the performance characteristics of air-cooled and water-cooled chillers, centrifugal and screw compressors, evaporators, condensers, cooling towers, pumps, and associated control systems. Particular attention is given to developing cooling plant configurations that accommodate current heat loads, future expansion requirements, variable IT demand, and stringent availability expectations without compromising energy efficiency or operational flexibility.
A major component of the programme focuses on chilled-water distribution engineering, including primary-secondary pumping, variable-primary flow systems, differential pressure control, hydraulic balancing, pipe sizing, and distribution network optimization. Participants examine the relationship between chilled-water supply temperatures, return temperatures, temperature differentials, flow rates, and cooling coil performance. The course also addresses the challenges of maintaining stable cooling delivery across multiple data halls, high-density server areas, liquid cooling distribution systems, and geographically distributed critical equipment rooms.
The programme provides advanced coverage of chiller plant energy efficiency and performance optimization. Participants investigate chiller coefficient of performance, integrated plant efficiency, cooling tower performance, pump energy consumption, variable-speed operation, heat exchanger effectiveness, and free-cooling opportunities. Practical engineering approaches are introduced for optimizing chilled-water temperature setpoints, condenser-water conditions, equipment sequencing, and plant operating strategies. Participants also examine how poor temperature differentials, excessive bypass flow, simultaneous heating and cooling, and inappropriate control sequences can increase energy consumption and reduce available cooling capacity.
Operational resilience and reliability are integrated throughout the training. Participants learn how to evaluate N+1 and other redundancy arrangements, assess equipment failure scenarios, develop isolation strategies, and verify the performance of standby chillers and pumps. The programme explores chiller plant commissioning, functional performance testing, integrated systems testing, condition monitoring, predictive maintenance, and fault diagnosis. Particular emphasis is placed on preventing cooling interruptions, maintaining thermal stability during equipment failures, and ensuring that cooling infrastructure can respond effectively to changing facility operating conditions.
The course also considers emerging developments in data center cooling, including high-temperature chilled-water systems, low-global-warming-potential refrigerants, thermal energy storage, intelligent plant controls, digital twins, and integration with direct-to-chip liquid cooling infrastructure. Participants examine the impact of high-density computing, AI workloads, sustainability targets, water conservation, and environmental regulations on future chiller plant design. By the end of the programme, participants will be better equipped to develop technically sound cooling strategies, improve chilled-water distribution performance, reduce cooling energy consumption, and maintain reliable thermal infrastructure throughout the operational lifecycle of modern data centers.
Duration
10 days
Who Should Attend
-
Data center mechanical engineers responsible for chiller plant design, cooling infrastructure, and mechanical system performance.
-
HVAC engineers involved in chilled-water system engineering, equipment selection, and cooling plant optimization.
-
Data center facility managers overseeing cooling operations, infrastructure availability, and energy performance.
-
Critical facilities engineers responsible for maintaining mission-critical cooling plants and distribution networks.
-
MEP design engineers involved in developing mechanical infrastructure for hyperscale, colocation, and enterprise data centers.
-
Commissioning engineers responsible for testing chillers, pumps, cooling towers, and integrated chilled-water systems.
-
Energy managers evaluating cooling plant efficiency, energy consumption, and operational improvement opportunities.
-
Project managers overseeing data center construction, cooling plant replacement, and infrastructure expansion projects.
-
Building services consultants developing resilient cooling solutions for high-density computing facilities.
-
Operations and maintenance personnel responsible for chiller servicing, pump maintenance, and cooling distribution equipment.
-
Sustainability professionals assessing cooling-related carbon emissions, water consumption, and environmental performance.
-
Reliability engineers evaluating cooling redundancy, equipment failure risks, and business continuity requirements.
-
Technical procurement specialists involved in specifying and evaluating chillers, pumps, heat exchangers, and HVAC control equipment.
-
Data center infrastructure planners developing long-term cooling capacity and mechanical infrastructure strategies.
Course Objectives
-
Understand advanced chiller plant engineering principles and evaluate how different chiller technologies support the thermal and operational requirements of mission-critical data centers.
-
Calculate cooling loads, plant capacity requirements, equipment redundancy allowances, and future expansion margins using appropriate engineering design assumptions.
-
Select suitable chiller configurations, compressors, evaporators, condensers, cooling towers, and auxiliary equipment based on operating conditions and reliability requirements.
-
Design chilled-water distribution networks that provide adequate flow, pressure, temperature stability, and cooling capacity across multiple data halls and critical equipment areas.
-
Evaluate primary-secondary and variable-primary pumping arrangements, including hydraulic behavior, control requirements, operational flexibility, and energy implications.
-
Analyze chilled-water temperature differentials, flow rates, differential pressure, and heat transfer performance to identify distribution inefficiencies and cooling capacity constraints.
-
Apply advanced control strategies for chiller sequencing, pump modulation, cooling tower operation, temperature reset, and plant optimization under changing IT loads.
-
Assess cooling plant energy performance using coefficient of performance, integrated plant efficiency, Power Usage Effectiveness, and other relevant performance indicators.
-
Identify opportunities to improve cooling efficiency through free cooling, economizer operation, heat recovery, thermal storage, and optimized operating temperature conditions.
-
Develop cooling infrastructure reliability strategies incorporating equipment redundancy, fault isolation, standby capacity, emergency operating procedures, and maintenance planning.
-
Apply commissioning, performance testing, monitoring, and troubleshooting methods to verify chiller plant operation and resolve chilled-water system performance problems.
-
Develop sustainable and future-ready cooling plant strategies that accommodate high-density computing, liquid cooling integration, environmental requirements, and long-term infrastructure growth.
Comprehensive Course Outline
Module 1: Fundamentals of Data Center Chiller Plant Engineering
-
Principles of refrigeration and chilled-water generation, including heat absorption, heat rejection, refrigerant compression, condensation, expansion, and evaporator operation.
-
Characteristics of data center cooling loads, including continuous IT heat generation, variable computing utilization, equipment diversity, and thermal design requirements.
-
Role of chiller plants within integrated data center mechanical infrastructure, including chilled-water production, distribution, cooling coils, and heat rejection systems.
-
Engineering considerations for cooling availability, operational continuity, maintainability, redundancy, and thermal stability in mission-critical facilities.
Module 2: Cooling Load Assessment and Chiller Plant Capacity Planning
-
Calculation of sensible and total cooling loads using IT equipment power consumption, electrical losses, lighting, occupancy, and environmental heat gains.
-
Assessment of peak, average, minimum, and variable cooling demands across data halls, technical rooms, support areas, and high-density computing zones.
-
Determination of chiller plant installed capacity, effective available capacity, redundancy margins, and future expansion allowances.
-
Development of cooling load profiles and capacity planning strategies that account for AI workloads, GPU deployments, equipment refresh cycles, and phased facility expansion.
Module 3: Chiller Technologies, Configurations and Equipment Selection
-
Technical comparison of air-cooled, water-cooled, centrifugal, screw, scroll, and other chiller technologies used in data center cooling applications.
-
Evaluation of compressor characteristics, evaporator and condenser arrangements, refrigerant selection, and equipment operating envelopes.
-
Selection of chiller capacity and configuration based on design ambient conditions, chilled-water temperatures, part-load performance, and reliability requirements.
-
Assessment of modular chiller arrangements, multiple-unit configurations, equipment turndown, serviceability, and future plant scalability.
Module 4: Advanced Chiller Plant Architecture and Redundancy Design
-
Development of centralized, distributed, modular, and campus-level chiller plant architectures for different data center sizes and operational requirements.
-
Engineering principles of N, N+1, 2N, and other redundancy configurations, including the relationship between installed capacity and usable cooling capacity.
-
Evaluation of chiller staging, standby equipment availability, isolation arrangements, and maintenance strategies that minimize cooling interruptions.
-
Design of resilient plant arrangements addressing common-mode failures, electrical supply interruptions, control system faults, and loss of critical mechanical components.
Module 5: Chilled-Water System Design and Hydraulic Distribution
-
Engineering design of chilled-water supply and return networks, including pipe sizing, flow calculations, pressure losses, material selection, and distribution arrangements.
-
Analysis of primary-secondary, primary-only, and variable-primary chilled-water pumping configurations and their application in data center facilities.
-
Design of distribution headers, risers, branch connections, isolation valves, balancing valves, strainers, and differential pressure control arrangements.
-
Evaluation of hydraulic separation, decoupler operation, bypass flow, minimum chiller flow requirements, and system stability under variable cooling loads.
Module 6: Pump Selection, Control and Energy Optimization
-
Fundamentals of pump hydraulics, including flow rate, total dynamic head, pump curves, operating points, efficiency, and system resistance characteristics.
-
Selection of chilled-water pumps and associated motors based on duty requirements, redundancy arrangements, operating conditions, and lifecycle costs.
-
Application of variable-frequency drives, differential pressure sensors, automatic control valves, and variable-flow pumping strategies.
-
Optimization of pump sequencing, speed control, hydraulic balancing, and differential pressure setpoints to reduce unnecessary energy consumption.
Module 7: Heat Exchangers, Cooling Coils and Thermal Transfer Performance
-
Engineering principles of plate-and-frame, shell-and-tube, and other heat exchanger configurations used in chilled-water and cooling distribution systems.
-
Assessment of heat exchanger capacity, approach temperature, effectiveness, fouling resistance, pressure drop, and thermal performance limitations.
-
Selection and optimization of air handling unit cooling coils, fan coil equipment, CRAH units, and liquid cooling heat exchangers.
-
Evaluation of temperature differences, fluid properties, heat transfer coefficients, and flow arrangements when improving cooling system performance.
Module 8: Cooling Towers, Condenser Water and Heat Rejection Integration
-
Engineering principles of cooling tower operation, including evaporative cooling, wet-bulb temperature, cooling range, approach, and heat rejection capacity.
-
Design and optimization of condenser-water networks, including pumps, piping, strainers, water treatment equipment, and heat exchanger connections.
-
Evaluation of induced-draft, forced-draft, open-circuit, closed-circuit, and hybrid cooling tower configurations for data center applications.
-
Optimization of condenser-water temperatures, cooling tower fan operation, water flow, and chiller-tower coordination under different ambient conditions.
Module 9: Chiller Plant Energy Efficiency and Performance Assessment
-
Evaluation of chiller coefficient of performance, energy efficiency ratio, integrated part-load value, and other relevant equipment performance indicators.
-
Assessment of overall plant efficiency by considering chiller compressors, chilled-water pumps, condenser-water pumps, cooling tower fans, and auxiliary systems.
-
Analysis of part-load performance, equipment sequencing, operating hours, load distribution, and seasonal variations in cooling energy consumption.
-
Development of energy benchmarking procedures and performance improvement strategies using plant monitoring data and equipment operating records.
Module 10: Advanced Cooling Control Strategies and Building Management Integration
-
Design of chiller plant control sequences covering equipment staging, load allocation, pump operation, cooling tower sequencing, and temperature management.
-
Application of building management systems, programmable controllers, sensors, actuators, and supervisory control platforms for integrated plant operation.
-
Development of chilled-water temperature reset, differential pressure reset, condenser-water optimization, and adaptive operating setpoints.
-
Integration of alarms, interlocks, operating schedules, equipment status monitoring, and control system failover arrangements for reliable operation.
Module 11: Free Cooling, Economizer Systems and Thermal Energy Storage
-
Engineering principles of air-side and water-side economizers, including operating conditions, heat exchanger arrangements, and cooling system integration.
-
Evaluation of waterside free cooling using cooling towers, dry coolers, plate heat exchangers, and suitable ambient temperature conditions.
-
Design and application of chilled-water storage tanks and thermal energy storage systems for peak-load management and operational resilience.
-
Assessment of free-cooling availability, energy savings, seasonal performance, control coordination, and economic feasibility in different climatic environments.
Module 12: Chiller Plant Integration with High-Density and Liquid Cooling Systems
-
Cooling distribution requirements for high-density racks, AI infrastructure, GPU clusters, and advanced high-performance computing equipment.
-
Integration of chilled-water plants with coolant distribution units, secondary liquid cooling loops, rear-door heat exchangers, and direct-to-chip systems.
-
Evaluation of temperature compatibility, heat exchanger capacity, hydraulic separation, flow requirements, and facility-side cooling interfaces.
-
Development of adaptable cooling architectures that support mixed air and liquid cooling technologies while preserving plant reliability and efficiency.
Module 13: Cooling Plant Monitoring, Instrumentation and Predictive Maintenance
-
Selection and application of temperature, pressure, flow, power, vibration, and water-quality instrumentation for chiller plant monitoring.
-
Development of key performance indicators and operational dashboards for assessing chiller efficiency, pump performance, cooling tower operation, and distribution conditions.
-
Application of condition-based maintenance, trend analysis, fault detection, and predictive analytics to identify developing mechanical and control system problems.
-
Use of digital twins and intelligent monitoring platforms to improve operational visibility, equipment lifecycle management, and cooling plant performance.
Module 14: Water Management, Refrigerants and Sustainable Cooling Engineering
-
Assessment of cooling tower water consumption, cycles of concentration, blowdown, evaporation losses, and water treatment requirements.
-
Evaluation of refrigerant environmental characteristics, global warming potential, regulatory considerations, and emerging low-impact refrigerant alternatives.
-
Application of water conservation strategies, dry cooling, hybrid heat rejection, improved water treatment, and responsible cooling system operation.
-
Evaluation of carbon emissions, lifecycle costs, energy consumption, and sustainability performance across alternative chiller plant configurations.
Module 15: Chiller Plant Commissioning, Testing and Troubleshooting
-
Development of inspection and commissioning procedures for chillers, pumps, cooling towers, heat exchangers, piping networks, and associated controls.
-
Execution of functional performance tests, equipment sequencing tests, flow verification, temperature differential checks, and integrated systems testing.
-
Diagnosis of common problems such as low temperature differential, inadequate flow, compressor trips, refrigerant faults, fouled heat exchangers, and unstable controls.
-
Development of maintenance procedures, failure response strategies, equipment isolation plans, and recovery procedures for critical cooling infrastructure.
Module 16: Advanced Chiller Plant Optimization and Future Infrastructure Planning
-
Development of comprehensive optimization programmes covering equipment replacement, plant sequencing, hydraulic improvements, control upgrades, and cooling capacity utilization.
-
Application of energy modelling, lifecycle cost analysis, operational benchmarking, and investment evaluation for chiller plant modernization projects.
-
Assessment of emerging technologies such as magnetic-bearing chillers, advanced compressor designs, intelligent controls, thermal storage, and heat recovery systems.
-
Preparation of long-term cooling infrastructure roadmaps addressing high-density computing growth, liquid cooling adoption, sustainability targets, and changing operational requirements.
Training Approach
This course will be delivered by our skilled trainers who have vast knowledge and experience as expert professionals in the fields. The course is taught in English and through a mix of theory, practical activities, group discussion and case studies. Course manuals and additional training materials will be provided to the participants upon completion of the training.
Tailor-Made Course
This course can also be tailor-made to meet organization requirement. For further inquiries, please contact us on: Email: training@upskilldevelopment.com Tel: +254 721 331 808
Training Venue
The training will be held at our Upskill Training Centre. We also offer training for a group (at a discount of 10% to 50%) at requested location all over the world. The Onsite course fee covers the course tuition, training materials, two break refreshments, buffet lunch, airport transfers, Upskill gift package, and guided tour.
Visa application, travel expenses, dinners, accommodation, insurance, and other personal expenses are catered by the participant
Certification
Participants will be issued with Upskill certificate upon completion of this course.
Airport Pickup and Accommodation
Airport pickup and accommodation is arranged upon request. For booking contact our Training Coordinator through Email: training@upskilldevelopment.com, +254 721 331 808
Terms of Payment:
Unless otherwise agreed between the two parties’ payment of the course fee should be done 3 working days before commencement of the training so as to enable us to prepare better.